Fachartikel in der Zeitschrift ACS Omega, online erschienen am 05.08.2026. Verfasst von Ke Xu und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Infectious Disease, Faculty of Medicine, Imperial College London, London SW7 2AZ, U.K. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, UK Research and Innovation, Engineering and Physical Sciences Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Point-of-Care (POC) portable devices have shown significant potential for rapid pathogen identification in limited-resource settings. Colorimetric LAMP (cLAMP)-based POC nucleic acid testing is particularly promising due to its speed, sensitivity, and simple visual readout. However, there is a need for a universal, automated color detection method to improve ease of use and reduce readout subjectivity using portable devices. We proposed an AI-driven workflow for automatic detection of multiple pathogens using cLAMP in a multitube strip format. Following sample extraction, reagent rehydration, and reaction incubation, the cLAMP panel was photographed with a portable device. The algorithm performed: (1) image preprocessing to locate tubes; (2) segmentation and cleaning to extract the liquid-filled region using deep learning and Otsu's binarization, followed by pixel cleaning; (3) empty tube and invalid control checks; and (4) color detection using relative Maximum Mean Discrepancy (MMD; a nonparametric statistical distance between the hue distributions of two tube images) to identify samples. The AI workflow was evaluated on 1,636 photos from 527 tests for the differential diagnosis of three panels, for skin-tropic viruses, respiratory viral pathogens, and malaria parasites, under various lighting conditions in POC environments. The AI workflow was compared to expert-adjudicated human visual readouts as the reference standard. Rejection of invalid photos, defined as panels containing empty tubes or failed controls, achieved 98.94%, 98.29%, and 96.68% accuracy (95% CI 97.83−99.57%, 96.97−99.15%, 94.13−98.33%) for the three panels, respectively. Misclassified images were caused by human mistakes or extreme lighting conditions. Color identification on accepted images achieved 99.97%, 100%, and 99.69% accuracy (95% CI 99.82−100% for Data set 1 and 98.27−99.99% for Data set 3; one-sided 95% lower bound 99.90% for Data set 2). This study demonstrates a reliable automatic color readout workflow for cLAMP-based nucleic acid detection, showing potential for integration into POC testing apps for cloud-based use.

Autor:innen und Institutionen

  • Department of Infectious Disease, Faculty of Medicine, Imperial College London, London SW7 2AZ, U.K.
  • Centre for Antimicrobial Optimisation, Imperial College London, Room 7S5, Commonwealth Building, Hammersmith Hospital Campus, Du Cane Road, London W12 0NN, U.K.
  • Department of Electrical and Electronic Engineering, Faculty of Engineering, Imperial College London, Exhibition Road, London SW7 2AZ, U.K.
  • Department of Infection and Immunity, Imperial College Healthcare NHS Trust, St Mary's Hospital, Praed Street, London W2 1NY, U.K.
  • MRC Unit the Gambia at the London School of Hygiene and Tropical Medicine, Atlantic Boulevard, PO Box 273, Fajara, Banjul 00220, The Gambia.
  • Unité de Recherche Clinique de Nanoro, Institut de Recherche En Sciences de la Santé, Bp 218 Ouaga 11, Nanoro, Boulkiemdé 10010, Burkina Faso.

ORCID-Profile: Ke Xu, Kenny Malpartida-Cardenas, Nicolas Moser, Jesus Rodriguez-Manzano

Förderung

  • Wellcome Trust
  • UK Research and Innovation
  • Engineering and Physical Sciences Research Council
  • Biotechnology and Biological Sciences Research Council
  • National Institute for Health and Care Research
  • Imperial College London
  • Department of Health, Imperial College London
  • Social Care-funded Centre for Antimicrobial Optimisation, Imperial College London

Zitieren

APA

Xu, K., Cavuto, M. L., Malpartida-Cardenas, K., Pond, M., Rakotomalala Robinson, D., Kiemde, F., Hernandez, B., Sriskandan, S., D'Alessandro, U., Erhart, A., Tinto, H., Cunnington, A. J., Holmes, A., Georgiou, P., Moser, N., & Rodriguez-Manzano, J. (2026). AI-Driven Workflow for Automated Colorimetric Isothermal Amplification for Robust Pathogen Detection on Portable Devices. ACS Omega, 11(32), 47285-47301. https://doi.org/10.1021/acsomega.5c12299

Vancouver

Xu K, Cavuto ML, Malpartida-Cardenas K, Pond M, Rakotomalala Robinson D, Kiemde F, et al. AI-Driven Workflow for Automated Colorimetric Isothermal Amplification for Robust Pathogen Detection on Portable Devices. ACS Omega. 2026;11(32):47285-47301. doi:10.1021/acsomega.5c12299

BibTeX
@article{Xu2026,
  author = {Xu, Ke and Cavuto, Matthew L and Malpartida-Cardenas, Kenny and Pond, Marcus and Rakotomalala Robinson, Dimbintsoa and Kiemde, Francois and Hernandez, Bernard and Sriskandan, Shiranee and D'Alessandro, Umberto and Erhart, Annette and Tinto, Halidou and Cunnington, Aubrey J and Holmes, Alison and Georgiou, Pantelis and Moser, Nicolas and Rodriguez-Manzano, Jesus},
  title = {AI-Driven Workflow for Automated Colorimetric Isothermal Amplification for Robust Pathogen Detection on Portable Devices},
  journal = {ACS Omega},
  year = {2026},
  volume = {11},
  number = {32},
  pages = {47285--47301},
  doi = {10.1021/acsomega.5c12299}
}
Kostenlos starten →