Simulations of Implanted Glutamate Sensor Performance in Three Spatial Dimensions and Time Inform Sensor Design and Data Interpretation
ACS Chemical Neuroscience · 2025
DOI: 10.1021/acschemneuro.5c00066 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Chemical Neuroscience, 2025. Verfasst von Mackenzie Clay und 2 weiteren Autor:innen. Beteiligte Einrichtung: Chemical and Biomolecular Engineering Dept, University of California, Los Angeles, Los Angeles, California 90095, United States. Hauptthemen laut MEDLINE: Glutamic Acid, Biosensing Techniques, Electrodes, Implanted. Die Arbeit nennt 60 Literaturangaben. Gefördert von: National Institute of Neurological Disorders and Stroke.
Abstract (Originalsprache)
Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements in vivo based on calibration factors determined in vitro. Calculations also show that crosstalk between glutamate sensors in a planar array due to lateral H2O2 diffusion is unimportant at micron-scale separation distances, but that the glutamate depletion zone in the vicinity of an individual sensor may limit site spacing to ≳40 μm. Deposition of immobilized glutamate oxidase layers that extend beyond the edge of the underlying microelectrode can improve sensitivity modestly, but H2O2 generated by the enzyme at the periphery may not be captured efficiently by the microelectrode, thereby resulting in potentially toxic local H2O2 concentrations of ∼25 μM. While simulations predict that detection of glutamate from single-vesicle release events in a synapse would result in current signals that are challenging to detect with conventional equipment, electroenzymatic sensors arranged in planar arrays on biocompatible probes will continue to be a powerful tool for neuroscientists.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical and Biomolecular Engineering Dept, University of California, Los Angeles, Los Angeles, California 90095, United States.
- Dept. of Psychiatry and Biobehavioral Sciences, University of California, Los Angeles, Los Angeles, California 90095, United States.
ORCID-Profile: Harold G Monbouquette
Förderung
- National Institute of Neurological Disorders and Stroke
Zitieren
APA
Clay, M., Maidment, N. T., & Monbouquette, H. G. (2025). Simulations of Implanted Glutamate Sensor Performance in Three Spatial Dimensions and Time Inform Sensor Design and Data Interpretation. ACS Chemical Neuroscience. https://doi.org/10.1021/acschemneuro.5c00066
Vancouver
Clay M, Maidment NT, Monbouquette HG. Simulations of Implanted Glutamate Sensor Performance in Three Spatial Dimensions and Time Inform Sensor Design and Data Interpretation. ACS Chemical Neuroscience. 2025. doi:10.1021/acschemneuro.5c00066
BibTeX
@article{Clay2025,
author = {Clay, Mackenzie and Maidment, Nigel T and Monbouquette, Harold G},
title = {Simulations of Implanted Glutamate Sensor Performance in Three Spatial Dimensions and Time Inform Sensor Design and Data Interpretation},
journal = {ACS Chemical Neuroscience},
year = {2025},
doi = {10.1021/acschemneuro.5c00066}
}
EUVIMED