EUVIMEDEUVIMED entdecken
Crossref

Design and Performance Analysis of a Bionic Radially Gradient Irregular Bone Scaffold

Qingyu Xu iD, Jizhe Hai, Jie Chen

ACS Biomaterials Science & Engineering · 10.08.2026 · 12 (8) · 4416-4432

DOI: 10.1021/acsbiomaterials.6c00612 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Biomaterials Science & Engineering, online erschienen am 14.07.2026. Verfasst von Qingyu Xu und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Ecology and Environment, Xinjiang University, Urumqi830017, China. Hauptthemen laut MEDLINE: Tissue Scaffolds, Bone and Bones. Die Arbeit nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Research and Development Tasks Program of the Xinjiang Uygur Autonomous Region.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Irregular porous scaffolds based on Voronoi tessellation have attracted growing interest in bone tissue engineering because their geometric heterogeneity more closely resembles native bone than conventional periodic lattices. However, current Voronoi scaffold designs remain largely limited to homogeneous or axially graded architectures, whereas radially graded irregular scaffolds for long-bone repair have been insufficiently explored. Here, nine biomimetic radially graded irregular scaffolds with a target porosity of 70% were developed by synergistically tailoring seed-point distribution (PG) and strut-diameter gradient (DG) within a Voronoi framework. Their geometric features, mechanical properties, mass transport behavior, and biofunctional performance were systematically evaluated through numerical analysis and experimental validation. The scaffolds exhibited elastic moduli of 4.09−7.29 GPa, yield strengths of 75.30−271.35 MPa, permeabilities of 1.93−2.71 × 10−8 m2, and cell adhesion rates of 2.93−9.31%. Seed-point distribution primarily governed permeability and cell adhesion, whereas strut-diameter grading had a stronger effect on mechanical behavior and mechano-regulated cell differentiation. Among all designs, the PG1-DG1 scaffold, featuring a radially decreasing porosity, exhibited the highest permeability (2.71 × 10−8 m2) and cell adhesion rate (9.31%) while maintaining a stress-transfer pattern more consistent with native long bone. These findings provide a rational design strategy for developing load-bearing biomimetic bone scaffolds with balanced mechanical and biological performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tissue ScaffoldsBone and BonesPorosityTissue EngineeringCell AdhesionAnimalsHumansBionicsCell DifferentiationElastic Modulus

Stichwörter der Autor:innen

Voronoi tessellationadditive manufacturingbionic performancegradient scaffoldmechanobiology

Autor:innen und Institutionen

  • School of Ecology and Environment, Xinjiang University, Urumqi830017, China.
  • School of Mechanical Engineering, Xinjiang University, Urumqi830017, China.

ORCID-Profile: Qingyu Xu

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Tasks Program of the Xinjiang Uygur Autonomous Region

Zitieren

APA

Xu, Q., Hai, J., & Chen, J. (2026). Design and Performance Analysis of a Bionic Radially Gradient Irregular Bone Scaffold. ACS Biomaterials Science & Engineering, 12(8), 4416-4432. https://doi.org/10.1021/acsbiomaterials.6c00612

Vancouver

Xu Q, Hai J, Chen J. Design and Performance Analysis of a Bionic Radially Gradient Irregular Bone Scaffold. ACS Biomaterials Science & Engineering. 2026;12(8):4416-4432. doi:10.1021/acsbiomaterials.6c00612

BibTeX
@article{Xu2026,
  author = {Xu, Qingyu and Hai, Jizhe and Chen, Jie},
  title = {Design and Performance Analysis of a Bionic Radially Gradient Irregular Bone Scaffold},
  journal = {ACS Biomaterials Science & Engineering},
  year = {2026},
  volume = {12},
  number = {8},
  pages = {4416--4432},
  doi = {10.1021/acsbiomaterials.6c00612}
}
Kostenlos starten →