EUVIMEDEUVIMED entdecken
Crossref

Small volume blood-brain barrier opening in macaques with a 1 MHz ultrasound phased array

Thomas J Manuel, Michelle K Sigona, M Anthony Phipps, Jiro Kusunose, Huiwen Luo, Pai-Feng Yang, Allen T Newton, John C Gore, William Grissom, Li Min Chen, Charles F Caskey

Journal of Controlled Release · 2023

DOI: 10.1016/j.jconrel.2023.10.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Controlled Release, 2023. Verfasst von Thomas J Manuel und 10 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA. Hauptthemen laut MEDLINE: Blood-Brain Barrier, Macaca. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 83 Literaturangaben. Gefördert von: NIMH NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of focused ultrasound to open the blood-brain barrier (BBB) has the potential to deliver drugs to specific regions of the brain. The size of the BBB opening and ability to localize the opening determines the spatial extent and is a limiting factor in many applications of BBB opening where targeting a small brain region is desired. Here we evaluate the performance of a system designed for small opening volumes and highlight the unique challenges associated with pushing the spatial precision of this technique. To achieve small volume openings in cortical regions of the macaque brain, we tested a custom 1 MHz array transducer integrated into a magnetic resonance image-guided focused ultrasound system. Using real-time cavitation monitoring, we demonstrated twelve instances of single sonication, small volume BBB opening with average volumes of 59 ± 37 mm3 and 184 ± 2 mm3 in cortical and subcortical targets, respectively. We found high correlation between subject-specific acoustic simulations and observed openings when incorporating grey matter segmentation (R2 = 0.8577), and the threshold for BBB opening based on simulations was 0.53 MPa. Analysis of MRI-based safety assessment and cavitation signals indicate a safe pressure range for 1 MHz BBB opening and suggest that our system can be used to deliver drugs and gene therapy to small brain regions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood-Brain BarrierMacacaAnimalsBrainUltrasonographySonicationMagnetic Resonance ImagingMicrobubbles

Stichwörter der Autor:innen

Blood-brain barrierFocused ultrasoundInterventional neuroradiologyMRIUltrasound

Autor:innen und Institutionen

  • Vanderbilt University, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
  • Vanderbilt University Medical Center, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
  • Vanderbilt University, Nashville, TN, USA; Vanderbilt University Medical Center, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA.
  • Vanderbilt University, Nashville, TN, USA; Vanderbilt University Medical Center, Nashville, TN, USA; Vanderbilt University Institute of Imaging Science, Nashville, TN, USA. Electronic address: charles.f.caskey@vumc.org.

Förderung

  • NIMH NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Manuel, T. J., Sigona, M. K., Phipps, M. A., Kusunose, J., Luo, H., Yang, P. F., Newton, A. T., Gore, J. C., Grissom, W., Chen, L. M., & Caskey, C. F. (2023). Small volume blood-brain barrier opening in macaques with a 1 MHz ultrasound phased array. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2023.10.015

Vancouver

Manuel TJ, Sigona MK, Phipps MA, Kusunose J, Luo H, Yang PF, et al. Small volume blood-brain barrier opening in macaques with a 1 MHz ultrasound phased array. Journal of Controlled Release. 2023. doi:10.1016/j.jconrel.2023.10.015

BibTeX
@article{Manuel2023,
  author = {Manuel, Thomas J and Sigona, Michelle K and Phipps, M Anthony and Kusunose, Jiro and Luo, Huiwen and Yang, Pai-Feng and Newton, Allen T and Gore, John C and Grissom, William and Chen, Li Min and Caskey, Charles F},
  title = {Small volume blood-brain barrier opening in macaques with a 1 MHz ultrasound phased array},
  journal = {Journal of Controlled Release},
  year = {2023},
  doi = {10.1016/j.jconrel.2023.10.015}
}
Kostenlos starten →