Combined Regulation of Macrophage Phagocytosis by the Size, Shape, and Mechanical Stiffness of Concave Core–Shell Artificial Oxygen Carriers
ACS Applied Materials & Interfaces · 2026
DOI: 10.1021/acsami.5c22955 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, 2026. Verfasst von Da Xiao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical System Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan. Hauptthemen laut MEDLINE: Phagocytosis, Oxygen, Macrophages. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Support for Pioneering Research Initiated by the Next Generation.
Abstract (Originalsprache)
Red blood cell-mimetic artificial oxygen carriers (AOCs) with concave morphology were developed as core-shell microparticles consisting of perfluorooctyl bromide and a polydimethylsiloxane-based thermoplastic elastomer (PFOB/PDMS-TPE). Their size, shape, and mechanical stiffness were tunable via a high-shear homogenization method, yielding diameters ranging from 2 μm (comparable to human platelets) to 8 μm (comparable to human red blood cells). These AOCs exhibited both oxygen-carrying capability and excellent in vitro biocompatibility. Compression testing demonstrated that apparent particle stiffness could be modulated by adjusting the core-to-shell (C/S) ratio without altering the material composition. Phagocytosis assays using RAW 264.7 macrophages showed that 2 μm-diameter spherical particles were readily internalized, whereas concave 2 μm-diameter AOCs exhibited markedly reduced uptake. In contrast, both 8 μm spherical particles and concave AOCs exhibited limited phagocytosis. Furthermore, competitive phagocytosis assays, in which macrophages were simultaneously exposed to two distinct AOC types, revealed a combined interplay among size, shape, and mechanical stiffness. Notably, 2 μm concave AOCs were phagocytosed less efficiently than 4 μm spherical counterparts, and concave AOCs, regardless of size, consistently evaded macrophage uptake under mixed-particle conditions. These findings provide key design principles for engineering deformable, shape-optimized microparticles, such as AOCs and drug-delivery carriers, that effectively evade macrophage phagocytosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical System Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
- Department of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
- Department of Radiology and Biomedical Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan.
ORCID-Profile: Natsuko F Inagaki, Taichi Ito
Förderung
- Japan Society for the Promotion of Science
- Support for Pioneering Research Initiated by the Next Generation
Zitieren
APA
Xiao, D., Inagaki, N. F., Chen, N., & Ito, T. (2026). Combined Regulation of Macrophage Phagocytosis by the Size, Shape, and Mechanical Stiffness of Concave Core–Shell Artificial Oxygen Carriers. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5c22955
Vancouver
Xiao D, Inagaki NF, Chen N, Ito T. Combined Regulation of Macrophage Phagocytosis by the Size, Shape, and Mechanical Stiffness of Concave Core–Shell Artificial Oxygen Carriers. ACS Applied Materials & Interfaces. 2026. doi:10.1021/acsami.5c22955
BibTeX
@article{Xiao2026,
author = {Xiao, Da and Inagaki, Natsuko F and Chen, Nan and Ito, Taichi},
title = {Combined Regulation of Macrophage Phagocytosis by the Size, Shape, and Mechanical Stiffness of Concave Core–Shell Artificial Oxygen Carriers},
journal = {ACS Applied Materials & Interfaces},
year = {2026},
doi = {10.1021/acsami.5c22955}
}
EUVIMED