Organic Electrochemical Transistors with Molecularly Imprinted Polymer Electrodes for Rapid Detection of Perfluorooctanoic Acid
ACS Applied Materials & Interfaces · 2025-04-30 · 17 (17) · 25582-25590
DOI: 10.1021/acsami.5c03362 ↗At a glance
Journal article in ACS Applied Materials & Interfaces, published online on 2025-04-17. Written by Sarah Adaryan and 3 co-authors. Institution: Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005, United States. Cited 19 times so far (Crossref); 50 references. Funded by: Division of Emerging Frontiers and Multidisciplinary Activities, U.S. Department of the Treasury, Office of Energy Efficiency and Renewable Energy.
Abstract (original language)
Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants linked to adverse health effects, and there is a need for sensors that can detect PFAS in challenging environments. Electrochemical sensors offer significant potential for achieving cost-effective, rapid, and real-time detection of PFAS, particularly in comparison to current detection techniques, which rely on costly chromatographic methods. Here, we report that organic electrochemical transistors (OECTs) containing a molecularly imprinted polymer (MIP) gate electrode can selectively detect perfluorooctanoic acid (PFOA) in seawater. We prepared a molecularly imprinted polyaniline (PANI) gate electrode by polymerizing aniline onto filter paper in the presence of PFOA, followed by rinsing to remove the PFOA. When used as a gate electrode in an organic electrochemical device (OECT), the presence of PFOA produced a measurable change in the OECT source-drain current due to adsorption of PFOA onto the gate electrode, which reduced capacitance and increased impedance. Other molecules produced a weak or no response. Specifically, we show that the device responds strongly to PFOA but only weakly to perfluoropropionic acid (PFPrA), perfluorohexanoic acid (PFHxA), and surfactant 4-dodecylbenzenesulfonic acid (DBSA). The device is also able to selectively detect PFOA in mixtures containing these other PFAS or surfactants. We achieved a detection limit of 1.6 parts per trillion (ppt) or 3.86 × 10-12 M, below the regulatory advisory level of 70 ppt set by the United States Environmental Protection Agency for PFOA. This work demonstrates low-cost sensors capable of rapid and molecularly specific detection of PFOA, which can potentially lead to low-cost sensors for monitoring the concentrations of PFOA and other PFAS in seawater and other challenging environments.
Subjects
Author keywords
Authors and institutions
- Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005, United States.
- Mechanical and Aerospace Engineering, University of Houston, Houston, Texas 77004, United States.
- Materials Science and NanoEngineering, Rice University, Houston, Texas 77005, United States.
ORCID profiles: Erin B Porter, Haleh Ardebili, Rafael Verduzco
Funding
- Division of Emerging Frontiers and Multidisciplinary Activities
- U.S. Department of the Treasury
- Office of Energy Efficiency and Renewable Energy
Cite
APA
Adaryan, S., Porter, E. B., Ardebili, H., & Verduzco, R. (2025). Organic Electrochemical Transistors with Molecularly Imprinted Polymer Electrodes for Rapid Detection of Perfluorooctanoic Acid. ACS Applied Materials & Interfaces, 17(17), 25582-25590. https://doi.org/10.1021/acsami.5c03362
Vancouver
Adaryan S, Porter EB, Ardebili H, Verduzco R. Organic Electrochemical Transistors with Molecularly Imprinted Polymer Electrodes for Rapid Detection of Perfluorooctanoic Acid. ACS Applied Materials & Interfaces. 2025;17(17):25582-25590. doi:10.1021/acsami.5c03362
BibTeX
@article{Adaryan2025,
author = {Adaryan, Sarah and Porter, Erin B and Ardebili, Haleh and Verduzco, Rafael},
title = {Organic Electrochemical Transistors with Molecularly Imprinted Polymer Electrodes for Rapid Detection of Perfluorooctanoic Acid},
journal = {ACS Applied Materials & Interfaces},
year = {2025},
volume = {17},
number = {17},
pages = {25582--25590},
doi = {10.1021/acsami.5c03362}
}
EUVIMED