Energy-Transfer-Based Dual-Mode PEC-ECL Biosensor for Acetamiprid Analysis Sensitized by Two-Step DNA Circuit Amplification
ACS Applied Materials & Interfaces · 2025-01-15 · 17 (2) · 3052-3061
DOI: 10.1021/acsami.4c18752 ↗At a glance
Journal article in ACS Applied Materials & Interfaces, published online on 2025-01-06. Written by Huan Yang and 3 co-authors. Institution: School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou 221116, China. Major MEDLINE topics: Neonicotinoids, Biosensing Techniques, Electrochemical Techniques. Cited 31 times so far (Crossref); 36 references. Funded by: Natural Science Foundation of Xuzhou Municipality, Six Talent Peaks Project in Jiangsu Province, National Natural Science Foundation of China.
Abstract (original language)
Sensitive and accurate determination of acetamiprid is highly desirable for guaranteeing food safety. In this Letter, an energy-transfer-based dual-mode biosensor was developed using zinc-based metal-organic frameworks (Zn-MOFs) acting as both photoelectrochemical (PEC) and electrochemiluminescent (ECL) donors and Pt@Cu2O cubic nanocrystals (CNs) as the energy acceptor for detecting acetamiprid. By integration of aptamer recognition with two-step DNA circuit amplification (entropy-driven DNA cycle and DNA walker), the detection of acetamiprid was converted into the assay of abundant intermediate DNA strands. With the help of nicking endonuclease, a large number of single-stranded DNAs was generated on the surface of Zn-MOFs, which were used as multifunctional PEC and ECL substrates. Through competitive hybridization, Pt@Cu2O CNs as broad-spectrum quenchers were introduced, thereby enabling changes in the PEC and ECL responses for acetamiprid quantitation. The experimental results proved that the combination of energy transfer, two-step DNA circuit amplification, and dual-mode sensing strategy achieved the sensitive and accurate analysis of acetamiprid, with low detection limits of 20.2 fM (PEC mode) and 17.5 fM (ECL mode) within a wide range from 0 to 1 × 10-9 M. The excellent specificity, reproducibility, and practicality confirmed the potential application of the biosensor for pesticide-related food safety.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- School of Chemistry and Materials Science, Jiangsu Normal University, Xuzhou 221116, China.
ORCID profiles: Po Wang, Qiumei Feng
Funding
- Natural Science Foundation of Xuzhou Municipality
- Six Talent Peaks Project in Jiangsu Province
- National Natural Science Foundation of China
Cite
APA
Yang, H., Wang, H., Wang, P., & Feng, Q. (2025). Energy-Transfer-Based Dual-Mode PEC-ECL Biosensor for Acetamiprid Analysis Sensitized by Two-Step DNA Circuit Amplification. ACS Applied Materials & Interfaces, 17(2), 3052-3061. https://doi.org/10.1021/acsami.4c18752
Vancouver
Yang H, Wang H, Wang P, Feng Q. Energy-Transfer-Based Dual-Mode PEC-ECL Biosensor for Acetamiprid Analysis Sensitized by Two-Step DNA Circuit Amplification. ACS Applied Materials & Interfaces. 2025;17(2):3052-3061. doi:10.1021/acsami.4c18752
BibTeX
@article{Yang2025,
author = {Yang, Huan and Wang, Huan and Wang, Po and Feng, Qiumei},
title = {Energy-Transfer-Based Dual-Mode PEC-ECL Biosensor for Acetamiprid Analysis Sensitized by Two-Step DNA Circuit Amplification},
journal = {ACS Applied Materials & Interfaces},
year = {2025},
volume = {17},
number = {2},
pages = {3052--3061},
doi = {10.1021/acsami.4c18752}
}
EUVIMED