EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Protein Stacking on the APTES-Functionalized Pyrochlore Bi 2 Ru 2 O 7 Clusters for Ultrasensitive and Selective Immunosensing

Nikola Tasić iD, Nika Vranešič, Dino Metarapi, Kristina Mervič iD, Milan Žunić, Aleksandra Dapčević, Matjaž Finšgar iD, Samo B Hočevar iD

ACS Applied Materials & Interfaces · 2025

DOI: 10.1021/acsami.4c17869 ↗

At a glance

Journal article in ACS Applied Materials & Interfaces, 2025. Written by Nikola Tasić and 7 co-authors. Institution: Department of Analytical Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana, Slovenia. Major MEDLINE topics: Biosensing Techniques, Silanes, SARS-CoV-2, Spike Glycoprotein, Coronavirus. Cited 3 times so far (Crossref); 45 references. The full text is freely available (open access, CC BY 4.0). Funded by: Javna Agencija za Raziskovalno Dejavnost RS, European Regional Development Fund, Ministrstvo za visoko ?olstvo, znanost in tehnologijo.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

High Resolution Image Download MS PowerPoint Slide With their unique physicochemical properties, such as metallic-like conductivity, favorable (electro)catalytic properties, electrochemical stability, and ease of functionalization, pyrochlores have found applications in various fields such as solid oxide fuel cells, batteries, thick film resistors, and temperature sensors; however, there are no reports on their application in electrochemical immunosensing. In this study, we exploited the (electro)catalytic nature and stability of the pyrochlore Bi 2 Ru 2 O 7 clusters silanized with (3-aminopropyl)triethoxysilane (APTES) to demonstrate their potential for the effective stacking of functional proteins. Characterization of the clusters by XPS disclosed a dual environment of Bi, also indicating the presence of Bi 2 O 3 alongside APTES-Bi 2 Ru 2 O 7 clusters and, importantly, the predominant involvement of pyrochlore moieties in subsequent protein stacking. After stacking protein A and antibodies, the immunosensor revealed a nearly interference-free operation, high sensitivity, a detection limit of 118 fM SARS-CoV-2 spike protein, and operation in a wide examined concentration range of 10 −5 −10 −1 μg mL −1 with an r 2 of 0.98. In combination with a short incubation time of 30 min, the pyrochlore-based immunosensor provides a solid platform for future point-of-need applications.

Subjects

MeSH terms (MEDLINE)

Biosensing TechniquesSilanesSARS-CoV-2Spike Glycoprotein, CoronavirusBismuthLimit of DetectionHumansImmunoassayPropylaminesElectrochemical TechniquesCOVID-19CopperOxides

Author keywords

APTESBi2Ru2O7 pyrochloreSARS-CoV-2electrochemicalimmunosensorimpedimetricspike protein

Substances

SilanesSpike Glycoprotein, CoronavirusBismuthPropylaminesspike protein, SARS-CoV-2amino-propyl-triethoxysilaneCopperOxides

Authors and institutions

  • Department of Analytical Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana, Slovenia.
  • University of Belgrade, Institute for Multidisciplinary Research, Kneza Višeslava 1, 11030 Belgrade, Serbia.
  • Department of General and Inorganic Chemistry, Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11000 Belgrade, Serbia.
  • Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova 17, 2000 Maribor, Slovenia.

ORCID profiles: Nikola Tasić, Kristina Mervič, Matjaž Finšgar, Samo B Hočevar

Funding

  • Javna Agencija za Raziskovalno Dejavnost RS
  • European Regional Development Fund
  • Ministrstvo za visoko ?olstvo, znanost in tehnologijo
  • Ministarstvo Prosvete, Nauke i Tehnolo?kog Razvoja

Cite

APA

Tasić, N., Vranešič, N., Metarapi, D., Mervič, K., Žunić, M., Dapčević, A., Finšgar, M., & Hočevar, S. B. (2025). Protein Stacking on the APTES-Functionalized Pyrochlore Bi 2 Ru 2 O 7 Clusters for Ultrasensitive and Selective Immunosensing. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.4c17869

Vancouver

Tasić N, Vranešič N, Metarapi D, Mervič K, Žunić M, Dapčević A, et al. Protein Stacking on the APTES-Functionalized Pyrochlore Bi 2 Ru 2 O 7 Clusters for Ultrasensitive and Selective Immunosensing. ACS Applied Materials & Interfaces. 2025. doi:10.1021/acsami.4c17869

BibTeX
@article{Tasi2025,
  author = {Tasić, Nikola and Vranešič, Nika and Metarapi, Dino and Mervič, Kristina and Žunić, Milan and Dapčević, Aleksandra and Finšgar, Matjaž and Hočevar, Samo B},
  title = {Protein Stacking on the APTES-Functionalized Pyrochlore Bi 2 Ru 2 O 7 Clusters for Ultrasensitive and Selective Immunosensing},
  journal = {ACS Applied Materials & Interfaces},
  year = {2025},
  doi = {10.1021/acsami.4c17869}
}
Start for free →