Highly Sensitive Flexible Capacitive Pressure Sensor Based on a Multicross-Linked Dual-Network Ionic Hydrogel for Blood Pressure Monitoring Applications
ACS Applied Materials & Interfaces · 2024
DOI: 10.1021/acsami.4c04686 ↗At a glance
Journal article in ACS Applied Materials & Interfaces, 2024. Written by Caixia Liu and 11 co-authors. Institution: College of Physics, Hefei University of Technology, Hefei 230009, China. Major MEDLINE topics: Hydrogels, Wearable Electronic Devices. Cited 45 times so far (Crossref); 68 references. Funded by: Science and Technology Department of Zhejiang Province, Anhui Provincial Department of Education.
Abstract (original language)
Flexible capacitive pressure sensors based on ionic hydrogels (IHs) have garnered significant attention in the field of wearable technology. However, the vulnerability of traditional single-network hydrogels to mechanical damage and the complexity associated with preparing double-network hydrogels present challenges in developing a highly sensitive, easily prepared, and durable IH-based flexible capacitive pressure sensor. This study introduces a novel multicross-linked dual-network IH achieved through the physical and chemical cross-linking of polymers polyvinyl alcohol (PVA) and chitosan (CS), ionic solution H3PO4, and cross-linking agent gum arabic. Flexible capacitive pressure sensors, characterized by high sensitivity and a broad pressure range, are fabricated by employing mesh as templates to design cut-corner cube microstructures with high uniformity and controllability on the IHs. The sensor exhibits high sensitivity across a wide pressure range (0-290 kPa) and with excellent features such as high resolution (∼1.3 Pa), fast response-recovery time (∼11 ms), and repeatable compression stability at 25 kPa (>2000 cycles). The IHs as a dielectric layer demonstrate long-term water retention properties, enabling exposure to air for up to 100 days. Additionally, the developed sensor shows the ability to accurately measure the pulse wave within the small pressure range. By combining the pulse wave acquired by the sensor with a trained neural network model, we achieve successful blood pressure (BP) prediction, meeting the standards set by the Association for the Advancement of Medical Instrumentation and the British Hypertension Society. Ultimately, the sensor proposed in this study holds promising prospects for broad applications in high-precision wearable medical electronic devices.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- College of Physics, Hefei University of Technology, Hefei 230009, China.
- College of Microelectronics, Hefei University of Technology, Hefei 230009, China.
ORCID profiles: Ping Liu, Yugang Zhang
Funding
- Science and Technology Department of Zhejiang Province
- Anhui Provincial Department of Education
Cite
APA
Liu, C., Ma, F., Sun, Q., Hu, Q., Tong, W., Guo, X., Hu, R., Liu, P., Huang, Y., Hao, X., Ma, W., & Zhang, Y. (2024). Highly Sensitive Flexible Capacitive Pressure Sensor Based on a Multicross-Linked Dual-Network Ionic Hydrogel for Blood Pressure Monitoring Applications. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.4c04686
Vancouver
Liu C, Ma F, Sun Q, Hu Q, Tong W, Guo X, et al. Highly Sensitive Flexible Capacitive Pressure Sensor Based on a Multicross-Linked Dual-Network Ionic Hydrogel for Blood Pressure Monitoring Applications. ACS Applied Materials & Interfaces. 2024. doi:10.1021/acsami.4c04686
BibTeX
@article{Liu2024,
author = {Liu, Caixia and Ma, Fei and Sun, Qichang and Hu, Qiusheng and Tong, Wei and Guo, Xu and Hu, Ruohai and Liu, Ping and Huang, Ying and Hao, Xingtong and Ma, Wenzhi and Zhang, Yugang},
title = {Highly Sensitive Flexible Capacitive Pressure Sensor Based on a Multicross-Linked Dual-Network Ionic Hydrogel for Blood Pressure Monitoring Applications},
journal = {ACS Applied Materials & Interfaces},
year = {2024},
doi = {10.1021/acsami.4c04686}
}
EUVIMED