A Nanoplasmonic Assay for Point-of-Care Detection of Mannose-Binding Lectin in Human Serum
ACS Applied Materials & Interfaces · 2024
DOI: 10.1021/acsami.4c04018 ↗At a glance
Journal article in ACS Applied Materials & Interfaces, 2024. Written by Alessia Pancaro and 9 co-authors. Institution: Health Unit, Flemish Institute for Technological Research (VITO), Boeretang 200, Mol 2400, Belgium. Major MEDLINE topics: Gold, Mannose-Binding Lectin, Point-of-Care Systems, Biosensing Techniques. Cited 6 times so far (Crossref); 69 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Universiteit Hasselt, H2020 Marie Sklodowska-Curie Actions, Vlaamse Instelling voor Technologisch Onderzoek.
Abstract (original language)
Mannose-binding lectin (MBL) activates the complement system lectin pathway and subsequent inflammatory mechanisms. The incidence and outcome of many human diseases, such as brain ischemia and infections, are associated with and influenced by the activity and serum concentrations of MBL in body fluids. To quantify MBL levels, tests based on ELISA are used, requiring several incubation and washing steps and lengthy turnaround times. Here, we aimed to develop a nanoplasmonic assay for direct MBL detection in human serum at the point of care. Our assay is based on gold nanorods (GNRs) functionalized with mannose (Man-GNRs) via an amphiphilic linker. We experimentally determined the effective amount of sugar linked to the nanorods' surface, resulting in an approximate grafting density of 4 molecules per nm2, and an average number of 11 to 13 MBL molecules binding to a single nanoparticle. The optimal Man-GNRs concentration to achieve the highest sensitivity in MBL detection was 15 μg·mL-1. The specificity of the assay for MBL detection both in simple buffer and in complex pooled human sera was confirmed. Our label-free biosensor is able to detect MBL concentrations as low as 160 ng·mL-1 within 15 min directly in human serum via a one-step reaction and by using a microplate reader. Hence, it forms the basis for a fast, noninvasive, point-of-care assay for diagnostic indications and monitoring of disease and therapy.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Health Unit, Flemish Institute for Technological Research (VITO), Boeretang 200, Mol 2400, Belgium.
- Dynamic Bioimaging Lab, Biomedical Research Institute, Hasselt University, Agoralaan C, Diepenbeek 3590, Belgium.
- Istituto di Scienze e Tecnologie Chimiche "Giulio Natta", SCITEC-CNR, G, Fantoli 16/15, Milan 20138, Italy.
- Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Mario Negri 2 20156, Milan, Italy.
- Midatech Pharma PLC, Oddfellows House, 19 Newport Road, Cardiff CF24 0AA, U.K.
- Advanced Optical Microscopy Centre, Biomedical Research Institute, Hasselt University, Agoralaan C, Diepenbeek 3590, Belgium.
ORCID profiles: Alessia Pancaro, Laura Polito, Marco Gobbi, Sam Duwé, Jelle Hendrix
Funding
- Universiteit Hasselt
- H2020 Marie Sklodowska-Curie Actions
- Vlaamse Instelling voor Technologisch Onderzoek
- Fonds Wetenschappelijk Onderzoek
- Bijzonder Onderzoeksfonds UGent
Cite
APA
Pancaro, A., Szymonik, M., Perez Schmidt, P., Erol, G., Garcia Barrientos, A., Polito, L., Gobbi, M., Duwé, S., Hendrix, J., & Nelissen, I. (2024). A Nanoplasmonic Assay for Point-of-Care Detection of Mannose-Binding Lectin in Human Serum. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.4c04018
Vancouver
Pancaro A, Szymonik M, Perez Schmidt P, Erol G, Garcia Barrientos A, Polito L, et al. A Nanoplasmonic Assay for Point-of-Care Detection of Mannose-Binding Lectin in Human Serum. ACS Applied Materials & Interfaces. 2024. doi:10.1021/acsami.4c04018
BibTeX
@article{Pancaro2024,
author = {Pancaro, Alessia and Szymonik, Michal and Perez Schmidt, Patricia and Erol, Gizem and Garcia Barrientos, Africa and Polito, Laura and Gobbi, Marco and Duwé, Sam and Hendrix, Jelle and Nelissen, Inge},
title = {A Nanoplasmonic Assay for Point-of-Care Detection of Mannose-Binding Lectin in Human Serum},
journal = {ACS Applied Materials & Interfaces},
year = {2024},
doi = {10.1021/acsami.4c04018}
}
EUVIMED