EUVIMEDEUVIMED entdecken
Crossref

Novel Dual-Emission Carbonized Polymer Dot-Based Ratiometric Fluorescence Probe for the Sensitive Detection of Tertiary Butylhydroquinone

Jiangbin Xu iD, Wei Yang iD, Yuanfa Liu iD

ACS Applied Materials & Interfaces · 07.06.2023 · 15 (22) · 27065-27074

DOI: 10.1021/acsami.3c03283 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 23.05.2023. Verfasst von Jiangbin Xu und 2 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food,…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Quantum Dots. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Ministry of Science and Technology of the People's Republic of China, Jiangsu Provincial Center of Technology Innovation for Future Food.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tertiary butylhydroquinone (TBHQ), one of the most common antioxidants in many foods, has attracted widespread attention due to its potential risk to human health. In this work, an "on-off-on" ratiometric fluorescent probe was prepared using dual-emission carbonized polymer dots (d-CPDs), which can be used to detect TBHQ in edible oils. The ratiometric fluorescent sensing system consisted of blue fluorescent CPDs (b-CPDs) as the response signal and yellow fluorescent CPDs (y-CPDs) as the internal reference material. The blue fluorescence of b-CPDs was gradually quenched with increasing Fe3+ ion concentration, while the yellow fluorescence was essentially unaffected. Interestingly, TBHQ can restore the fluorescence intensity of b-CPDs. Meanwhile, the fluorescence mechanism of Fe3+ on b-CPDs was investigated by density functional theory, both after the addition of TBHQ, and CPDs were released and their fluorescence was restored due to the competitive reaction of TBHQ-Fe3+. Thus, the d-CPDs probe was able to detect Fe3+ accurately in an "on-off" manner and thus TBHQ in an "off-on" manner. At an optimal Fe3+ concentration, the ratiometric sensing system provided fine linearities for determining TBHQ in the range from 0.2 to 2 μM and an ingenious detection limit of 0.052 μM. The CPDs ratiometric fluorescent probe designed in this work may have a broader application in the rapid, susceptive, and low-cost determination of TBHQ in various foods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesQuantum DotsHumansFluorescencePolymersOilsHydroquinones

Stichwörter der Autor:innen

DFT calculationcarbonized polymer dots (CPDs)ratiometric fluorescence probetertiary butylhydroquinone (TBHQ)vegetable oil safety

Substanzen

Fluorescent DyesPolymersOils2-tert-butylhydroquinoneHydroquinones

Autor:innen und Institutionen

  • State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, National Engineering Laboratory for Cereal Fermentation Technology, C…
  • Future Food (Bai Ma) Research Institute, 111 Baima Road, Nanjing 211200, Jiangsu, People's Republic of China.

ORCID-Profile: Jiangbin Xu, Wei Yang, Yuanfa Liu

Förderung

  • Ministry of Science and Technology of the People's Republic of China
  • Jiangsu Provincial Center of Technology Innovation for Future Food

Zitieren

APA

Xu, J., Yang, W., & Liu, Y. (2023). Novel Dual-Emission Carbonized Polymer Dot-Based Ratiometric Fluorescence Probe for the Sensitive Detection of Tertiary Butylhydroquinone. ACS Applied Materials & Interfaces, 15(22), 27065-27074. https://doi.org/10.1021/acsami.3c03283

Vancouver

Xu J, Yang W, Liu Y. Novel Dual-Emission Carbonized Polymer Dot-Based Ratiometric Fluorescence Probe for the Sensitive Detection of Tertiary Butylhydroquinone. ACS Applied Materials & Interfaces. 2023;15(22):27065-27074. doi:10.1021/acsami.3c03283

BibTeX
@article{Xu2023,
  author = {Xu, Jiangbin and Yang, Wei and Liu, Yuanfa},
  title = {Novel Dual-Emission Carbonized Polymer Dot-Based Ratiometric Fluorescence Probe for the Sensitive Detection of Tertiary Butylhydroquinone},
  journal = {ACS Applied Materials & Interfaces},
  year = {2023},
  volume = {15},
  number = {22},
  pages = {27065--27074},
  doi = {10.1021/acsami.3c03283}
}
Kostenlos starten →