EUVIMEDEUVIMED entdecken
Crossref

Plant-wearable fluorescent hydrogel patch based on PDA-PEI copolymer dots for on-site visual detection of glyphosate

Shuqi Wang, Shuzhen Zheng, Hongzhi Lu, Changsheng Wang, Shoufang Xu

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.346219 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Shuqi Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Linyi University, Linyi, 276005, China; Laboratory of Functional Polymers, School of Materials Science …. Hauptthemen laut MEDLINE: Glycine, Polymers, Polyethyleneimine, Indoles. Die Arbeit nennt 52 Literaturangaben. Gefördert von: National College Students Innovation and Entrepreneurship Training Program, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Glyphosate (GLY) residues are difficult to remove from agricultural products and pose potential risks to food safety, making their sensitive detection highly desirable. In this study, a Cu2+-mediated ratiometric fluorescence sensing platform was constructed for the sensitive detection of GLY by physically mixing polydopamine-polyethyleneimine copolymer dots (PDA-PEI CPDs) with terephthalic acid (PTA) based on a competitive coordination strategy. RESULTS: Cu2+ coordinated with the amino groups on the surface of CPDs and the carboxyl groups of PTA to form a CPDs-PTA-Cu2+ complex. This process quenched the green fluorescence of CPDs at 530 nm while generating a new blue emission at 450 nm. Upon the addition of GLY, competitive coordination between GLY and Cu2+ disrupted the complex, resulting in fluorescence recovery at 530 nm and fluorescence quenching at 450 nm, thereby producing a ratiometric fluorescence response. The sensor shows linear ranges of 0-80 μg/mL for GLY (LOD = 5.73 ng/mL). To meet the requirements of on-site applications, a CPDs-Cu2+@sodium alginate hydrogel was further prepared. Under 365 nm excitation, the hydrogel responded to GLY through single-emission fluorescence recovery at 530 nm. The hydrogel enabled smartphone-assisted RGB quantitative analysis and in situ semi-quantitative screening of GLY on vegetable surfaces using a wearable hydrogel patch. SIGNIFICANCE: By integrating solution-phase ratiometric fluorescence quantification with hydrogel-based visual readout, a simple and portable sensing platform was established for accurate GLY determination and visual screening of surface residues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlycinePolymersPolyethyleneimineIndolesHydrogelsFluorescent DyesQuantum DotsGlyphosateCopperFluorescent Chemosensor CompoundsSpectrometry, FluorescenceLimit of DetectionFluorescence

Stichwörter der Autor:innen

GlyphosatePlant-wearable hydrogelPolydopamine-polyethyleneimine copolymer dotsRatiometric fluorescenceSmartphone-assisted analysis

Substanzen

GlyphosateGlycinePolymersPolyethyleneimineIndolespolydopamineHydrogelsCopperFluorescent DyesFluorescent Chemosensor Compounds

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Linyi University, Linyi, 276005, China; Laboratory of Functional Polymers, School of Materials Science and Engineering, Linyi University, Linyi, 276005, China.
  • School of Chemistry and Chemical Engineering, Linyi University, Linyi, 276005, China.
  • School of Chemistry and Chemical Engineering, Linyi University, Linyi, 276005, China. Electronic address: luhongzhi@126.com.
  • Laboratory of Functional Polymers, School of Materials Science and Engineering, Linyi University, Linyi, 276005, China.
  • Laboratory of Functional Polymers, School of Materials Science and Engineering, Linyi University, Linyi, 276005, China. Electronic address: shfxu1981@163.com.

Förderung

  • National College Students Innovation and Entrepreneurship Training Program
  • Natural Science Foundation of Shandong Province

Zitieren

APA

Wang, S., Zheng, S., Lu, H., Wang, C., & Xu, S. (2026). Plant-wearable fluorescent hydrogel patch based on PDA-PEI copolymer dots for on-site visual detection of glyphosate. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346219

Vancouver

Wang S, Zheng S, Lu H, Wang C, Xu S. Plant-wearable fluorescent hydrogel patch based on PDA-PEI copolymer dots for on-site visual detection of glyphosate. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346219

BibTeX
@article{Wang2026,
  author = {Wang, Shuqi and Zheng, Shuzhen and Lu, Hongzhi and Wang, Changsheng and Xu, Shoufang},
  title = {Plant-wearable fluorescent hydrogel patch based on PDA-PEI copolymer dots for on-site visual detection of glyphosate},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.346219}
}
Kostenlos starten →