EUVIMEDObjevte EUVIMED
Crossref

High-Intensity Focused Ultrasound Combined with Ti 3 C 2 –TiO 2 to Enhance Electrochemiluminescence of Luminol for the Sensitive Detection of Polynucleotide Kinase

Zhihao Wei, Huixin Zhang, Zonghua Wang iD

ACS Applied Materials & Interfaces · 2023

DOI: 10.1021/acsami.2c19539 ↗

At a glance

Journal article in ACS Applied Materials & Interfaces, 2023. Written by Zhihao Wei and 2 co-authors. Institution: College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Centre for Collaborative Research of Carbon Nanomaterials, Instrumental Analysi…. Major MEDLINE topics: Biosensing Techniques, Metal Nanoparticles. Cited 28 times so far (Crossref); 41 references. Funded by: Natural Science Foundation of Shandong Province, Key Project of Innovative Teaching Laboratory of Qingdao University in 2020, Taishan Scholar Foundation of Shandong Province.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Luminol is a classic electrochemiluminescence (ECL) luminophore. The luminol-O2 ECL system suffers from a problem, that is, the conversion rate of dissolved O2 into reactive oxygen species (ROS) is low. In this work, we used high-intensity focused ultrasound (HIFU) pretreatment combined with Ti3C2-TiO2 to construct a highly sensitive luminol-O2 ECL system for the specific detection of polynucleotide kinase (PNK) first. On the one hand, HIFU generated ROS in situ as a coreactant via the cavitation effect to boost the luminol emission. On the other hand, Ti3C2-TiO2 was prepared in situ via Ti3C2 as a reducing agent, and it can aggregate and catalyze ROS generated in situ by HIFU. Moreover, the Ti on the Ti3C2-TiO2 surface could bind to phosphate groups through chelation, thereby realizing highly specific detection of PNK. The sensor has a linear relationship range of 1.0 × 10-5 to 10.0 U mL-1, and the limit of detection is 1.48 × 10-7 U mL-1, which is superior to most existing methods. The sensor performance in HeLa cell lysate was measured with a satisfactory result. The designed ECL biosensor has potential applications in biological analysis and clinical diagnosis.

Subjects

MeSH terms (MEDLINE)

Biosensing TechniquesMetal NanoparticlesHumansLuminolTitaniumPolynucleotide 5'-Hydroxyl-KinaseReactive Oxygen SpeciesHeLa CellsLuminescent MeasurementsElectrochemical TechniquesLimit of Detection

Author keywords

Ti3C2−TiO2electrochemiluminescencehigh-intensity focused ultrasoundluminol−O2polynucleotide kinase

Substances

Luminoltitanium dioxideTitaniumPolynucleotide 5'-Hydroxyl-KinaseReactive Oxygen Species

Authors and institutions

  • College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Centre for Collaborative Research of Carbon Nanomaterials, Instrumental Analysis Centre of Qingdao University, Institute of Biomedical Engineering, Q…

ORCID profiles: Zonghua Wang

Funding

  • Natural Science Foundation of Shandong Province
  • Key Project of Innovative Teaching Laboratory of Qingdao University in 2020
  • Taishan Scholar Foundation of Shandong Province

Cite

APA

Wei, Z., Zhang, H., & Wang, Z. (2023). High-Intensity Focused Ultrasound Combined with Ti 3 C 2 –TiO 2 to Enhance Electrochemiluminescence of Luminol for the Sensitive Detection of Polynucleotide Kinase. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.2c19539

Vancouver

Wei Z, Zhang H, Wang Z. High-Intensity Focused Ultrasound Combined with Ti 3 C 2 –TiO 2 to Enhance Electrochemiluminescence of Luminol for the Sensitive Detection of Polynucleotide Kinase. ACS Applied Materials & Interfaces. 2023. doi:10.1021/acsami.2c19539

BibTeX
@article{Wei2023,
  author = {Wei, Zhihao and Zhang, Huixin and Wang, Zonghua},
  title = {High-Intensity Focused Ultrasound Combined with Ti 3 C 2 –TiO 2 to Enhance Electrochemiluminescence of Luminol for the Sensitive Detection of Polynucleotide Kinase},
  journal = {ACS Applied Materials & Interfaces},
  year = {2023},
  doi = {10.1021/acsami.2c19539}
}
Start for free →