EUVIMEDEUVIMED entdecken
Crossref

Biased Pairing and DNA-based Docking of Two Different Types of Monodisperse Micrometer-Sized Liposomes in a Microfluidic Device

Haruto Obuchi, Yiting Zhang iD, Keita Abe, Shogo Hamada iD, Kaoru Uesugi, Teijiro Isokawa, Akihiro Inada, Hironori Sugiyama iD, Satoshi Murata, Taro Toyota iD

ACS Applied Bio Materials · 2026

DOI: 10.1021/acsabm.6c01189 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2026. Verfasst von Haruto Obuchi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Basic Science, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo153-8902, Japan. Hauptthemen laut MEDLINE: Liposomes, DNA, Lab-On-A-Chip Devices, Biocompatible Materials. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Ministry of Education, Culture, Sports, Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recent advances in prototissue construction have highlighted the importance of organizing multiple artificial cells with distinct function and intercellular communication capabilities. Previous approaches, including the use of optical tweezers, phoresis driven by the magneto-Archimedes effect, and 3D-printing, enabled the aggregation of liposome-based artificial cells, but they lacked precise spatial organization of individual artificial cells for large-scale production. Microfluidic devices (MFDs) offer potential for high-throughput prototissue fabrication but have faced challenges in achieving precise ordering of fragile liposomes with diameters exceeding 1 µm. In this study, we demonstrated an MFD incorporating U-shaped microstructures designed for liposome trapping that enables stochastic liposome capture and release, with this process being influenced by differences in the mechanical properties of the liposomal membrane. Based on these findings, we developed a two-step loading strategy, involving the sequential introduction of two liposome types, and successfully arranged them within the trapping microstructures of the MFD. Furthermore, DNA modification of the liposomes enhanced their spatial proximity within the MFD, enabling DNA hybridization and strand displacement reactions between the adjacent liposomal membranes. This MFD platform provides a statistical assay for constructing and analyzing minimal prototissues composed of two heterogeneous micrometer-sized liposomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiposomesDNALab-On-A-Chip DevicesBiocompatible MaterialsMicrofluidic Analytical TechniquesParticle SizeMaterials Testing

Stichwörter der Autor:innen

DNA hybridizationhydrodynamic manipulationmicrofluidic devicemicrometer-sized liposomestrand displacement reaction

Substanzen

LiposomesDNABiocompatible Materials

Autor:innen und Institutionen

  • Department of Basic Science, Graduate School of Arts and Sciences, The University of Tokyo, 3-8-1 Komaba, Meguro-ku, Tokyo153-8902, Japan.
  • Department of Robotics, Graduate School of Engineering, Tohoku University, 6-6-01, Aoba, Aramaki, Aoba-ku, Sendai, Miyagi980-8579, Japan.
  • Department of Computer Science, School of Computing, Institute of Science Tokyo, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa226-8501, Japan.
  • Department of Systems and Control Engineering, School of Engineering, Institute of Science Tokyo, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa226-8501, Japan.
  • Research Center for Autonomous Systems Materialogy, Institute of Science Tokyo, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa226-8501, Japan.
  • Biomolecular Design Institute, CBI Research Institute, 3-11-1 Shibaura, Minato-ku, Tokyo108-0023, Japan.

ORCID-Profile: Yiting Zhang, Shogo Hamada, Hironori Sugiyama, Taro Toyota

Förderung

  • Japan Society for the Promotion of Science
  • Ministry of Education, Culture, Sports, Science and Technology

Zitieren

APA

Obuchi, H., Zhang, Y., Abe, K., Hamada, S., Uesugi, K., Isokawa, T., Inada, A., Sugiyama, H., Murata, S., & Toyota, T. (2026). Biased Pairing and DNA-based Docking of Two Different Types of Monodisperse Micrometer-Sized Liposomes in a Microfluidic Device. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.6c01189

Vancouver

Obuchi H, Zhang Y, Abe K, Hamada S, Uesugi K, Isokawa T, et al. Biased Pairing and DNA-based Docking of Two Different Types of Monodisperse Micrometer-Sized Liposomes in a Microfluidic Device. ACS Applied Bio Materials. 2026. doi:10.1021/acsabm.6c01189

BibTeX
@article{Obuchi2026,
  author = {Obuchi, Haruto and Zhang, Yiting and Abe, Keita and Hamada, Shogo and Uesugi, Kaoru and Isokawa, Teijiro and Inada, Akihiro and Sugiyama, Hironori and Murata, Satoshi and Toyota, Taro},
  title = {Biased Pairing and DNA-based Docking of Two Different Types of Monodisperse Micrometer-Sized Liposomes in a Microfluidic Device},
  journal = {ACS Applied Bio Materials},
  year = {2026},
  doi = {10.1021/acsabm.6c01189}
}
Kostenlos starten →