EUVIMEDEUVIMED entdecken
Crossref

Smartphone-Enabled Electrochemical Biosensor for Simultaneous Detection of Cancer Biomarkers Using f-WS2@AuNPs Screen-Printed Electrodes

Hema Bhardwaj, G B V S Lakshmi, Pratima R Solanki iD

ACS Applied Bio Materials · 2025

DOI: 10.1021/acsabm.5c01571 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2025. Verfasst von Hema Bhardwaj und 2 weiteren Autor:innen. Beteiligte Einrichtung: Nano-bio Laboratory, Special Centre for Nanoscience, Jawaharlal Nehru University, New Delhi110067, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Biomarkers, Tumor, Electrochemical Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Department of Biotechnology, Ministry of Science and Technology, India, Department of Science and Technology, Ministry of Science and Technology, India, Indian Council of Medical Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present work focuses on the development of a disposable electrochemical biosensor for simultaneous dual cancer biomarker detection onto a single-sensing platform. For this, an indigenously designed four-electrode system having two working areas of electrodes on a single screen-printed electrode (SPE) substrate was coated by graphite-based conductive ink. The first working electrode surface decorated by the prepared complex is composed of chitosan-functionalized 1T phase of tungsten disulfide-gold nanoparticles (f-WS2@AuNPs) composite and activated antibodies of tagged Cancer Antigen 125 (ab-tg-CA-125), while the second working electrode contained f-WS2@AuNPs and antibody of Human Epididymis protein 4 (ab-HE4). Further, both working electrodes were passivated by BSA to block nonspecific signals. Dual antibody-immobilized platforms of ab-tg-CA-125/f-WS2@AuNPs/SPE and ab-HE4/f-WS2@AuNPs/SPE were further used for simultaneous detection of two ovarian cancer biomarkers of CA-125 and HE4 using an electrochemical differential pulse voltammetry (DPV) technique. Fabricated electrochemical immunosensing platforms of ab-tg-CA-125/f-WS2@AuNPs/SPE and ab-HE4/f-WS2@AuNPs/SPE worked in the range of 0.001–25 μg mL–1 for CA-125 detection and 0.001–10 ng mL–1 for HE4 detection. The developed immunosensor showed a limit of detection of 0.001 μg mL–1 for CA-125 and 0.001 ng mL–1 for HE4. Also, the sensitivity of the developed electrochemical biosensor was calculated for CA-125 and HE4 and found to be 1.43 μA(log μg mL–1)−1 cm–2 and 1.092 μA(log ng mL–1)−1 cm–2, respectively. Both ab-CA-125 and ab-HE4 antibodies exhibit a larger value of association constant (Ka) and reveals strong binding affinity of antibodies toward respective cancer biomarkers. Moreover, the developed biosensors were tested with clinical ovarian patient serum samples, and the results were compared with the immunoassay kit. Therefore, these findings show the effective biosensor performance in terms of sensitivity, selectivity, accuracy, and faster response for simultaneous ovarian biomarker detection in clinical samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesBiomarkers, TumorElectrochemical TechniquesMetal NanoparticlesSmartphoneHumansGoldElectrodesWAP Four-Disulfide Core Domain Protein 2CA-125 AntigenParticle SizeSurface PropertiesMaterials TestingDisulfides

Stichwörter der Autor:innen

duplexelectrochemical biosensorovarian cancer biomarkerssimultaneous detectiontwo-dimensional nanosheets

Substanzen

GoldBiomarkers, TumorWAP Four-Disulfide Core Domain Protein 2WFDC2 protein, humanCA-125 AntigenDisulfides

Autor:innen und Institutionen

  • Nano-bio Laboratory, Special Centre for Nanoscience, Jawaharlal Nehru University, New Delhi110067, India.

ORCID-Profile: Pratima R Solanki

Förderung

  • Department of Biotechnology, Ministry of Science and Technology, India
  • Department of Science and Technology, Ministry of Science and Technology, India
  • Indian Council of Medical Research
  • Department of Health Research, India

Zitieren

APA

Bhardwaj, H., Lakshmi, G. B. V. S., & Solanki, P. R. (2025). Smartphone-Enabled Electrochemical Biosensor for Simultaneous Detection of Cancer Biomarkers Using f-WS2@AuNPs Screen-Printed Electrodes. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.5c01571

Vancouver

Bhardwaj H, Lakshmi GBVS, Solanki PR. Smartphone-Enabled Electrochemical Biosensor for Simultaneous Detection of Cancer Biomarkers Using f-WS2@AuNPs Screen-Printed Electrodes. ACS Applied Bio Materials. 2025. doi:10.1021/acsabm.5c01571

BibTeX
@article{Bhardwaj2025,
  author = {Bhardwaj, Hema and Lakshmi, G B V S and Solanki, Pratima R},
  title = {Smartphone-Enabled Electrochemical Biosensor for Simultaneous Detection of Cancer Biomarkers Using f-WS2@AuNPs Screen-Printed Electrodes},
  journal = {ACS Applied Bio Materials},
  year = {2025},
  doi = {10.1021/acsabm.5c01571}
}
Kostenlos starten →