Highly Sensitive Phase-Engineered Copper Sulfide Interfaces for Nonenzymatic Electrochemical Creatinine Sensing in Human Urine

Srishti Verma, Gorachand Dutta iD

Langmuir · 07.07.2026 · 42 (26) · 19029-19045

DOI: 10.1021/acs.langmuir.6c01752 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, online erschienen am 23.06.2026. Verfasst von Srishti Verma und 1 weiteren Autor:innen. Beteiligte Einrichtung: NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India. Hauptthemen laut MEDLINE: Copper, Electrochemical Techniques, Creatinine. Die Arbeit nennt 62 Literaturangaben. Gefördert von: TIH Foundation for IoT and loE (TIH- IoT), IIT Bombay.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Herein, we report for the first time the exploration of PVP-modulated copper sulfide for a high-performance electrochemical nonenzymatic sensor for noninvasive creatinine sensing. A controlled coprecipitation route in the presence of polyvinylpyrrolidone (PVP) yields phase-pure Cu 7 S 4, while synthesis without PVP results in a heterogeneous mixture of Cu 6 S 6, Cu 7 S 4, and secondary phases (Cu x S). Electrochemical evaluation by cyclic voltammetry demonstrates that the phase-engineered PVP-modulated Cu 7 S 4 sensor exhibits a stable, well-defined cathodic complexation response, in contrast to Cu x S-based sensor. Mechanistic understanding was further advanced through high-resolution XPS at potentials associated with redox transitions and Copper–Creatinine complexation, confirming the role of surface Cu 2+ species and the C═N group of creatinine in facilitating electron transfer. The sensor demonstrated exceptional analytical figures of merit, including a wide linear range of 0–300 μM, encompassing the entire physiological and pathological range, a low detection limit of 1.196 μM, and a high sensitivity of 541.83 μA mM –1 cm –2 . Furthermore, the sensor exhibited splendid specificity, effectively mitigating uric acid interference through simple 100-fold dilution, and maintained remarkable stability with a 96.68% signal retention over 26 days. Crucially, validation using clinical human urine samples showed excellent agreement with the gold standard test ( P > 0.05). The PXRD, FTIR, Raman spectroscopy, UV–visible, FESEM, HR-TEM, Zeta potential, and XPS were performed for comprehensive material characterization, which revealed crucial phase engineering and functionalization influencing electrocatalytic activity. This study establishes phase-engineered PVP-modulated Cu 7 S 4 as a robust and reproducible nonenzymatic sensing material offering mechanistic insights that can guide the design of next-generation point-of-care creatinine sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperElectrochemical TechniquesCreatinineHumansPovidoneSurface Properties

Substanzen

CopperCreatininePovidone

Autor:innen und Institutionen

  • NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
  • School of Nano Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.

ORCID-Profile: Gorachand Dutta

Förderung

  • TIH Foundation for IoT and loE (TIH- IoT), IIT Bombay

Zitieren

APA

Verma, S., & Dutta, G. (2026). Highly Sensitive Phase-Engineered Copper Sulfide Interfaces for Nonenzymatic Electrochemical Creatinine Sensing in Human Urine. Langmuir, 42(26), 19029-19045. https://doi.org/10.1021/acs.langmuir.6c01752

Vancouver

Verma S, Dutta G. Highly Sensitive Phase-Engineered Copper Sulfide Interfaces for Nonenzymatic Electrochemical Creatinine Sensing in Human Urine. Langmuir. 2026;42(26):19029-19045. doi:10.1021/acs.langmuir.6c01752

BibTeX
@article{Verma2026,
  author = {Verma, Srishti and Dutta, Gorachand},
  title = {Highly Sensitive Phase-Engineered Copper Sulfide Interfaces for Nonenzymatic Electrochemical Creatinine Sensing in Human Urine},
  journal = {Langmuir},
  year = {2026},
  volume = {42},
  number = {26},
  pages = {19029--19045},
  doi = {10.1021/acs.langmuir.6c01752}
}
Kostenlos starten →