EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-Selectivity Nonenzymatic Creatinine Sensor Using Electrografted Ionic Liquid and Nafion for Reliable Clinical Diagnostics

Shih-Hao Lin, Jing-Chun Wang, Zong-Hong Lin iD, Fu-Cheng Kao, Hsiang-Yu Wang iD

ACS Sensors · 2025

DOI: 10.1021/acssensors.5c01503 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2025. Verfasst von Shih-Hao Lin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering and System Science, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan. Hauptthemen laut MEDLINE: Creatinine, Fluorocarbon Polymers, Ionic Liquids, Electrochemical Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid and accurate detection of creatinine is essential for monitoring kidney function and diagnosing renal impairments. Nonenzymatic catalysts have been used to improve sensitivity and reduce environmental susceptibility in creatinine detection. However, limited selectivity hinders their broader application in practical scenarios. This study introduced a novel nonenzymatic creatinine sensor that utilized copper(II) oxide as a catalyst, incorporating styrenyl-triphenylphosphonium-based ionic liquid (STPP-IL) and Nafion on the electrode surface to enhance selectivity and minimize interference. Electrografting technique ensured uniform STPP-IL coverage on the electrode, as confirmed by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). The modified creatinine sensors demonstrated a detection range from 1.5 to 800 μM with low standard error and high sensitivities in the presence of interferents. Notably, creatinine levels in the artificial and natural human sweat were selectively quantified using the proposed sensor, supporting its potential for clinical applications. The sensors retained over 90% of their initial current response after 40 days of storage. Additionally, reproducibility experiments demonstrated a relative error of 1.3% across five independent sensors. These results show the sensor's enhanced selectivity, stability, and reproducibility, making it a promising alternative for reliable creatinine detection in point-of-care tests.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CreatinineFluorocarbon PolymersIonic LiquidsElectrochemical TechniquesHumansElectrodesCopperReproducibility of Results

Stichwörter der Autor:innen

CuONPsNafioncreatinineelectrograftingstyrenyl-triphenylphosphonium-based ionic liquid

Substanzen

CreatinineFluorocarbon PolymersIonic Liquidsperfluorosulfonic acidCopper

Autor:innen und Institutionen

  • Department of Engineering and System Science, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan.
  • Department of Biomedical Engineering, National Taiwan University, No.1, Section 4, Roosevelt Road, Taipei 106319, Taiwan.
  • Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, No. 5, Fuxing St., Guishan Dist., Taoyuan City 33305, Taiwan.
  • College of Medicine, Chang Gung University, No.259, Wenhua first Rd., Guishan Dist., Taoyuan City 33302, Taiwan.
  • Institute of Nuclear Engineering, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan.

ORCID-Profile: Zong-Hong Lin, Hsiang-Yu Wang

Förderung

  • National Science and Technology Council

Zitieren

APA

Lin, S. H., Wang, J. C., Lin, Z. H., Kao, F. C., & Wang, H. Y. (2025). High-Selectivity Nonenzymatic Creatinine Sensor Using Electrografted Ionic Liquid and Nafion for Reliable Clinical Diagnostics. ACS Sensors. https://doi.org/10.1021/acssensors.5c01503

Vancouver

Lin SH, Wang JC, Lin ZH, Kao FC, Wang HY. High-Selectivity Nonenzymatic Creatinine Sensor Using Electrografted Ionic Liquid and Nafion for Reliable Clinical Diagnostics. ACS Sensors. 2025. doi:10.1021/acssensors.5c01503

BibTeX
@article{Lin2025,
  author = {Lin, Shih-Hao and Wang, Jing-Chun and Lin, Zong-Hong and Kao, Fu-Cheng and Wang, Hsiang-Yu},
  title = {High-Selectivity Nonenzymatic Creatinine Sensor Using Electrografted Ionic Liquid and Nafion for Reliable Clinical Diagnostics},
  journal = {ACS Sensors},
  year = {2025},
  doi = {10.1021/acssensors.5c01503}
}
Kostenlos starten →