EUVIMEDEUVIMED entdecken
Crossref

Application of a Near-Infrared Fluorescence Probe Based on Perylene Bisimide in the Detection of Heparin

Yueji Li, Yuteng Zhang, Xue Liu, Bin Dong iD, Pan Xu, Bo Song iD

Langmuir · 2024

DOI: 10.1021/acs.langmuir.4c03578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, 2024. Verfasst von Yueji Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, PR China. Hauptthemen laut MEDLINE: Perylene, Heparin, Imides, Fluorescent Dyes. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Collaborative Innovation Center of Suzhou Nano Science and Technology, State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, Soochow University, Priority Academic Program Development of Jiangsu Higher Education Institutions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heparin is widely used to treat thrombosis because it is an effective anticoagulant. However, excessive use of heparin can lead to an increased risk of bleeding, which makes the quantitative detection of heparin very important. An amphiphilic perylene bisimide molecule (denoted PBI-9) was developed, which presented a near-infrared emission peak at 730 nm when it was aggregated. PBI-9 has been utilized in the detection of heparin, as the pyridine cation in PBI-9 binds strongly to highly sulfated heparin through electrostatic interactions. Charge neutralization triggers the self-assembly of PBI-9, which leads to an emission peak shift from 540 nm to 690 nm, corresponding to monomeric emission to excimer emission. This shift was applied for the detection of heparin. Importantly, the interaction between PBI-9 and heparin is not affected by protamine, resulting in high selectivity and minimal interference. PBI-9 is a promising tool for detecting heparin in clinical settings after excess heparin has been neutralized by protamine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PeryleneHeparinImidesFluorescent DyesSpectrometry, FluorescenceHumansProtamines

Substanzen

PeryleneHeparinperylene bisimideImidesFluorescent DyesProtamines

Autor:innen und Institutionen

  • College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, PR China.

ORCID-Profile: Bin Dong, Bo Song

Förderung

  • Collaborative Innovation Center of Suzhou Nano Science and Technology
  • State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials, Soochow University
  • Priority Academic Program Development of Jiangsu Higher Education Institutions
  • Suzhou Key Laboratory of Macromolecular Design and Precision Synthesis
  • Jiangsu Key Laboratory of Advanced Functional Polymer Materials

Zitieren

APA

Li, Y., Zhang, Y., Liu, X., Dong, B., Xu, P., & Song, B. (2024). Application of a Near-Infrared Fluorescence Probe Based on Perylene Bisimide in the Detection of Heparin. Langmuir. https://doi.org/10.1021/acs.langmuir.4c03578

Vancouver

Li Y, Zhang Y, Liu X, Dong B, Xu P, Song B. Application of a Near-Infrared Fluorescence Probe Based on Perylene Bisimide in the Detection of Heparin. Langmuir. 2024. doi:10.1021/acs.langmuir.4c03578

BibTeX
@article{Li2024,
  author = {Li, Yueji and Zhang, Yuteng and Liu, Xue and Dong, Bin and Xu, Pan and Song, Bo},
  title = {Application of a Near-Infrared Fluorescence Probe Based on Perylene Bisimide in the Detection of Heparin},
  journal = {Langmuir},
  year = {2024},
  doi = {10.1021/acs.langmuir.4c03578}
}
Kostenlos starten →