EUVIMEDEUVIMED entdecken
Crossref

Design of “Off-On-Off” fluorescence sensors for Heparin detection by precise modulation of molecular structure

Yanan Li, Jian Cao, Chuanxiao Wang, Yiyi Qiao, Jiayu Gao, Xiao Zhang, Le Wang

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2024

DOI: 10.1016/j.saa.2024.124630 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2024. Verfasst von Yanan Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai 201620, PR China. Hauptthemen laut MEDLINE: Heparin, Fluorescence Resonance Energy Transfer, Limit of Detection. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this strategy, the fluorescence sensor Nap-Co-T1 employing the fluorescence resonance energy transfer (FRET) mechanism was designed and synthesized to have an efficient response to Heparin, and the FRET mechanism was explored for different excitation-emission wavelengths with different distances between the energy acceptor and the energy donor (comparing with fluorescence sensor Nap-TPA-T2). Upon the addition of Heparin, the fluorescence emission of Nap-Co-T1 was turned on at 565 nm, and the fluorescence color changed of the solution from colorless to bright yellow. The limit of detection (LOD) was as low as 0.04 μg/mL. With the addition of antagonistic protamine (PRTM) to the sensor complex with Heparin, the fluorescence emission was turned off to a certain extent, and the reversibility of the "off-on-off" system was maintained for five cycles or more. In addition, Nap-Co-T1 provides rapid and sensitive detection of Heparin in human serum albumin solution and artificial urine and is highly sensitive to environmental viscosity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeparinFluorescence Resonance Energy TransferLimit of DetectionHumansFluorescent DyesProtaminesSpectrometry, Fluorescence

Stichwörter der Autor:innen

Artificial urineFRET mechanismFluorescenceHeparinSensorViscosity

Substanzen

HeparinFluorescent DyesProtamines

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai 201620, PR China.
  • School of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai 201620, PR China. Electronic address: caoj@sues.edu.cn.

Zitieren

APA

Li, Y., Cao, J., Wang, C., Qiao, Y., Gao, J., Zhang, X., & Wang, L. (2024). Design of “Off-On-Off” fluorescence sensors for Heparin detection by precise modulation of molecular structure. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2024.124630

Vancouver

Li Y, Cao J, Wang C, Qiao Y, Gao J, Zhang X, et al. Design of “Off-On-Off” fluorescence sensors for Heparin detection by precise modulation of molecular structure. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2024. doi:10.1016/j.saa.2024.124630

BibTeX
@article{Li2024,
  author = {Li, Yanan and Cao, Jian and Wang, Chuanxiao and Qiao, Yiyi and Gao, Jiayu and Zhang, Xiao and Wang, Le},
  title = {Design of “Off-On-Off” fluorescence sensors for Heparin detection by precise modulation of molecular structure},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2024},
  doi = {10.1016/j.saa.2024.124630}
}
Kostenlos starten →