EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Schottky Interface Enabled Electrospun Rhodium Oxide Doped Gold for Both pH Sensing and Glucose Measurements in Neutral Buffer and Human Serum

Weiyu Xiao, Mingman Li, Danlei Li, Bo Shi, Runze Zhong, Yiyuan Zhao, Qingliang Tai, Songbing He, Qiuchen Dong iD

Langmuir · 2024

DOI: 10.1021/acs.langmuir.4c02999 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, 2024. Verfasst von Weiyu Xiao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, School of Science, Xi'an Jiaotong-Liverpool University, No. 111 Ren'ai Road, Suzhou Industrial Park, Dushu Lake Higher Educa…. Hauptthemen laut MEDLINE: Gold, Rhodium. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Xi?an Jiaotong-Liverpool University, New Pharmaceutics and Medical Apparatuses Project of Suzhou City of China, Gusu Medical Key Talent Project of Suzhou City of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study has focused on adjusting sensing environment from basic to neutral pH and improve sensing performance by doping electrodeposited gold (Au) with metal oxide for nonenzymatic glucose measurements in forming a Schottky interface for superior glucose sensing with detailed analysis for the sensing mechanism. The prepared sensor also holds the ability to measure pH with the identical electrospun metal oxide-electrodeposited Au, which composed a dual sensor (glucose and pH sensor) through applying chronoamperometry and open circuit potential methods. The rhodium oxide nanocoral structure was fabricated with an electrospinning precursor solution, followed by a calcination process, and it was mixed with electrodeposited nanocoral gold to form the Schottky interface by constructing a p-n type heterogeneous junction for improved sensitivity in glucose detection. The prepared materials were characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectrometry (XPS), etc. The prepared materials were used for both pH responsive testing and amperometric glucose measurements. The rhodium oxide nanocoral doped gold demonstrated a sensitivity of 3.52 μA mM-1 cm-2 and limit of detection of 20 μM with linear range up to 3 mM glucose concentration compared to solely electrodeposited gold for a sensitivity of 0.46 μA mM-1 cm-2 and a limit of detection of 450 μM. The Mott-Schottky method was used for the analysis of an electron transfer process from noble metal to metal oxide to electrolyte in demonstrating the improved sensitivity at neutral pH for glucose measurements due to the Schottky barrier adjustment mechanism at an applied flat band potential of 0.3 V. This work opens a new venue in illustrating the metal oxide/metal materials in the glucose neutral response mechanism. In the end, human serum samples were tested against current commercial glucose meter to certify the accuracy of the proposed sensor.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GoldRhodiumHumansHydrogen-Ion ConcentrationBlood GlucoseGlucoseElectrochemical TechniquesOxidesBuffersBiosensing Techniques

Substanzen

GoldRhodiumBlood GlucoseGlucoseOxidesBuffers

Autor:innen und Institutionen

  • Department of Chemistry, School of Science, Xi'an Jiaotong-Liverpool University, No. 111 Ren'ai Road, Suzhou Industrial Park, Dushu Lake Higher Education and Innovation Park, Suzhou 215123, Jiangsu Province, People's Re…
  • Department of General Surgery, First Affiliated Hospital of Soochow University, No. 188 Shizi Street, Suzhou 215006, Jiangsu Province, People's Republic of China.

ORCID-Profile: Qiuchen Dong

Förderung

  • Xi?an Jiaotong-Liverpool University
  • New Pharmaceutics and Medical Apparatuses Project of Suzhou City of China
  • Gusu Medical Key Talent Project of Suzhou City of China

Zitieren

APA

Xiao, W., Li, M., Li, D., Shi, B., Zhong, R., Zhao, Y., Tai, Q., He, S., & Dong, Q. (2024). Schottky Interface Enabled Electrospun Rhodium Oxide Doped Gold for Both pH Sensing and Glucose Measurements in Neutral Buffer and Human Serum. Langmuir. https://doi.org/10.1021/acs.langmuir.4c02999

Vancouver

Xiao W, Li M, Li D, Shi B, Zhong R, Zhao Y, et al. Schottky Interface Enabled Electrospun Rhodium Oxide Doped Gold for Both pH Sensing and Glucose Measurements in Neutral Buffer and Human Serum. Langmuir. 2024. doi:10.1021/acs.langmuir.4c02999

BibTeX
@article{Xiao2024,
  author = {Xiao, Weiyu and Li, Mingman and Li, Danlei and Shi, Bo and Zhong, Runze and Zhao, Yiyuan and Tai, Qingliang and He, Songbing and Dong, Qiuchen},
  title = {Schottky Interface Enabled Electrospun Rhodium Oxide Doped Gold for Both pH Sensing and Glucose Measurements in Neutral Buffer and Human Serum},
  journal = {Langmuir},
  year = {2024},
  doi = {10.1021/acs.langmuir.4c02999}
}
Kostenlos starten →