EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution

Emilio Molina Rueda iD, Ellison Carter, Christian L'Orange, Casey Quinn iD, John Volckens iD

Environmental Science & Technology Letters · 14.03.2023 · 10 (3) · 247-253

DOI: 10.1021/acs.estlett.3c00030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Science & Technology Letters, online erschienen am 08.02.2023. Verfasst von Emilio Molina Rueda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States. Die Arbeit wurde bisher 116-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIOSH CDC HHS, ACL HHS, National Institute for Occupational Safety and Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Particulate matter (PM) air pollution is a major health hazard. The health effects of PM are closely linked to particle size, which governs its deposition in (and penetration through) the respiratory tract. In recent years, low-cost sensors that report particle concentrations for multiple-sized fractions (PM1.0, PM2.5, PM10) have proliferated in everyday use and scientific research. However, knowledge of how well these sensors perform across the full range of reported particle size fractions is limited. Unfortunately, erroneous particle size data can lead to spurious conclusions about exposure, misguided interventions, and ineffectual policy decisions. We assessed the linearity, bias, and precision of three low-cost sensor models, as a function of PM size fraction, in an urban setting. Contrary to manufacturers' claims, sensors are only accurate for the smallest size fraction (PM1). The PM1.0-2.5 and PM2.5-10 size fractions had large bias, noise, and uncertainty. These results demonstrate that low-cost aerosol sensors (1) cannot discriminate particle size accurately and (2) only report linear and precise measures of aerosol concentration in the accumulation mode size range (i.e., between 0.1 and 1 μm). We recommend that crowdsourced air quality monitoring networks stop reporting coarse (PM2.5-10) mode and PM10 mass concentrations from these sensors.

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.
  • Department of Civil and Environmental Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.

ORCID-Profile: Emilio Molina Rueda, Casey Quinn, John Volckens

Förderung

  • NIOSH CDC HHS
  • ACL HHS
  • National Institute for Occupational Safety and Health

Zitieren

APA

Molina Rueda, E., Carter, E., L'Orange, C., Quinn, C., & Volckens, J. (2023). Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution. Environmental Science & Technology Letters, 10(3), 247-253. https://doi.org/10.1021/acs.estlett.3c00030

Vancouver

Molina Rueda E, Carter E, L'Orange C, Quinn C, Volckens J. Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution. Environmental Science & Technology Letters. 2023;10(3):247-253. doi:10.1021/acs.estlett.3c00030

BibTeX
@article{MolinaRueda2023,
  author = {Molina Rueda, Emilio and Carter, Ellison and L'Orange, Christian and Quinn, Casey and Volckens, John},
  title = {Size-Resolved Field Performance of Low-Cost Sensors for Particulate Matter Air Pollution},
  journal = {Environmental Science & Technology Letters},
  year = {2023},
  volume = {10},
  number = {3},
  pages = {247--253},
  doi = {10.1021/acs.estlett.3c00030}
}