Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure
Environmental Science & Technology · 02.11.2026
DOI: 10.1021/acs.est.6c06672 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 02.11.2026. Verfasst von Jenny Li-Liao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry & Chemical Biology, McMaster University, L8S 4L8Hamilton, Ontario, Canada. Hauptthemen laut MEDLINE: Inhalation Exposure, Environmental Monitoring. Die Arbeit nennt 98 Literaturangaben. Gefördert von: McMaster University, Ontario Research Foundation, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Calibrated wearable passive air samplers are critical tools for accessibly quantifying individualized and population exposures to airborne pollution, a leading cause of chronic disease. Our lab recently introduced passive sampling eyewear (PSE) to address gaps in tools tailored for measuring and mitigating risks from inhalation exposure. The PSE, like most existing designs of wearable samplers, is largely uncalibrated. An exception is the polydimethylsiloxane (PDMS) brooch, and mini-polyurethane foam (PUF) samplers, which have been calibrated for only 27 compounds. Here, we calibrate PSE against active air samplers codeployed in both stationary and wearable forms in office and home environments to capture a wide range of exposure scenarios. We report sampling rates (RS) and inhalation exposure for over 200 features covering diverse physical-chemical properties measured using the Orbitrap gas chromatography coupled to mass spectrometry (GC–MS) system in both targeted and nontargeted modes. RS were 0.70 ± 0.62 m3 day–1 dm–2 for stationary and 0.85 ± 0.68 m3 day–1 dm–2 for wearable deployments, with no significant difference (p = 0.06) between the deployment types. Wearable calibration captured higher RS and variability, as expected for personal sampling, because participants’ movement and daily activity can alter airflow and disrupt the stagnant air-boundary layer around the sampler. In terms of analysis mode, RS derived from targeted and nontargeted analysis (NTA) were reasonably comparable for a given compound, differing by ∼1.5-fold, boosting confidence in using NTA approaches for expanding databases of RS. Applying the wearable RS, the profiles and levels of inhalation exposure varied widely between participants when at home versus in offices, reflecting differences in exposure sources and dynamics between the two environments. Overall, the findings from both the calibration and field studies represent a significant step toward quantitatively assessing inhalation exposure using PSE.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry & Chemical Biology, McMaster University, L8S 4L8Hamilton, Ontario, Canada.
ORCID-Profile: Jenny Li-Liao, Anya Guo, Joseph O Okeme
Förderung
- McMaster University
- Ontario Research Foundation
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation
Zitieren
APA
Li-Liao, J., Pastore, I., Vaezafshar, S., Tsang, C., Guo, A., & Okeme, J. O. (2026). Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure. Environmental Science & Technology. https://doi.org/10.1021/acs.est.6c06672
Vancouver
Li-Liao J, Pastore I, Vaezafshar S, Tsang C, Guo A, Okeme JO. Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure. Environmental Science & Technology. 2026. doi:10.1021/acs.est.6c06672
BibTeX
@article{LiLiao2026,
author = {Li-Liao, Jenny and Pastore, Isabella and Vaezafshar, Sara and Tsang, Camille and Guo, Anya and Okeme, Joseph O},
title = {Calibration of Passive Sampling Eyewear to Assess Inhalation Exposure},
journal = {Environmental Science & Technology},
year = {2026},
doi = {10.1021/acs.est.6c06672}
}
EUVIMED