Using Suction Lysimeters for Determining the Potential of Per- and Polyfluoroalkyl Substances to Leach from Soil to Groundwater: A Review
Environmental Science & Technology · 2025
DOI: 10.1021/acs.est.4c10246 ↗At a glance
Übersichtsarbeit in Environmental Science & Technology, 2025. Written by Jed Costanza and 4 co-authors. Institution: Office of Superfund Remediation and Technology Innovation, U.S. Environmental Protection Agency, Washington, D.C. 20460, United States. Major MEDLINE topics: Groundwater, Soil, Fluorocarbons, Environmental Monitoring. Cited 16 times so far (Crossref); 112 references. The full text is freely available in PubMed Central. Funded by: Intramural EPA.
Abstract (original language)
In-situ porewater samples were proposed to best represent the fraction of perfluoroalkyl and polyfluoroalkyl substances (PFAS) with the potential to migrate to groundwater. While there are many techniques for collecting porewater samples, suction lysimeters are frequently being used for PFAS investigations. Suction lysimeters use vacuum to extract porewater from vadose zone soils, typically fine to medium sands, which retain and release enough porewater for analysis. Importantly, determining the rate of PFAS migration to groundwater requires an independent measure of water percolation. This review covers the installation and sampling methods for suction lysimeters and provides suggestions to improve the utility and reduce the variability of the results. Because the volume of soil represented by the porewater sample varies significantly depending on the soil-water content, which is spatially and temporally variable, many suction lysimeters may be required to accurately represent soil heterogeneity. A similar limitation applies to soil or leaching protocol samples. Suction lysimeters may not provide a representative sample for all PFAS due to interactions with lysimeter materials, air-water interfaces, and the use of vacuum. Consequently, lysimeter data are best applied in combination with soil-leaching protocols, groundwater transects, and soil analysis when making remedial decisions.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Office of Superfund Remediation and Technology Innovation, U.S. Environmental Protection Agency, Washington, D.C. 20460, United States.
- U.S. Environmental Protection Agency, Region 10, Seattle, Washington 98101, United States.
- U.S. Environmental Protection Agency, Region 8, Denver, Colorado 80202, United States.
- U.S. Environmental Protection Agency, Region 4, Atlanta, Georgia 30303, United States.
- Office of Research and Development, U.S. Environmental Protection Agency, Ada, Oklahoma 74820, United States.
ORCID profiles: Jed Costanza, Richard T Wilkin
Funding
- Intramural EPA
Cite
APA
Costanza, J., Clabaugh, C. D., Leibli, C., Ferreira, J., & Wilkin, R. T. (2025). Using Suction Lysimeters for Determining the Potential of Per- and Polyfluoroalkyl Substances to Leach from Soil to Groundwater: A Review. Environmental Science & Technology. https://doi.org/10.1021/acs.est.4c10246
Vancouver
Costanza J, Clabaugh CD, Leibli C, Ferreira J, Wilkin RT. Using Suction Lysimeters for Determining the Potential of Per- and Polyfluoroalkyl Substances to Leach from Soil to Groundwater: A Review. Environmental Science & Technology. 2025. doi:10.1021/acs.est.4c10246
BibTeX
@article{Costanza2025,
author = {Costanza, Jed and Clabaugh, Charles D and Leibli, Christa and Ferreira, James and Wilkin, Richard T},
title = {Using Suction Lysimeters for Determining the Potential of Per- and Polyfluoroalkyl Substances to Leach from Soil to Groundwater: A Review},
journal = {Environmental Science & Technology},
year = {2025},
doi = {10.1021/acs.est.4c10246}
}
EUVIMED