A Scalable Calibration Method for Enhanced Accuracy in Dense Air Quality Monitoring Networks

Anna R Winter iD, Yishu Zhu, Naomi G Asimow iD, Milan Y Patel iD, Ronald C Cohen iD

Environmental Science & Technology · 11.02.2025 · 59 (5) · 2599-2610

DOI: 10.1021/acs.est.4c08855 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 28.01.2025. Verfasst von Anna R Winter und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of California Berkeley, Berkeley, California 94720, United States. Hauptthemen laut MEDLINE: Environmental Monitoring. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Deployment of large numbers of low capital cost sensors to increase the spatial density of air quality measurements enables applications that build on mapping air at neighborhood scales. Effective deployment requires not only low capital costs for observations but also a simultaneous reduction in labor costs. The Berkeley Environmental Air Quality and CO2 Network (BEACO2N) is a sensor network measuring O3, CO, NO, and NO2, particulate matter (PM2.5), and CO2 at dozens of locations in cities where it is deployed. Here, we describe a low labor cost in situ field calibration for the BEACO2N O3, CO, NO, and NO2 sensors. This method identifies and leverages uniform periods in concentrations across the network for calibration. The calibration achieves high accuracy and low biases with respect to temperature, humidity, and concentration, with coefficients of determination and root mean square errors of 0.88 and 3.70 ppb for O3, 0.66 and 3.16 ppb for NO2, and 0.79 and 1.58 ppb for NO. Performance of the CO sensor is 0.90 and 33.3 ppb at a site colocated with reference measurements. The method is a crucial step toward lowering operational costs of delivering accurate measurements in dense networks employing large numbers of inexpensive air quality sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Environmental MonitoringCalibrationParticulate MatterAir PollutionAir Pollutants

Stichwörter der Autor:innen

CalibrationCarbon MonoxideLow-Cost SensorsNitric OxideNitrogen DioxideOzoneSensor Networks

Substanzen

Particulate MatterAir Pollutants

Autor:innen und Institutionen

  • Department of Chemistry, University of California Berkeley, Berkeley, California 94720, United States.
  • Department of Earth and Planetary Science, University of California Berkeley, Berkeley, California 94720, United States.

ORCID-Profile: Anna R Winter, Naomi G Asimow, Milan Y Patel, Ronald C Cohen

Zitieren

APA

Winter, A. R., Zhu, Y., Asimow, N. G., Patel, M. Y., & Cohen, R. C. (2025). A Scalable Calibration Method for Enhanced Accuracy in Dense Air Quality Monitoring Networks. Environmental Science & Technology, 59(5), 2599-2610. https://doi.org/10.1021/acs.est.4c08855

Vancouver

Winter AR, Zhu Y, Asimow NG, Patel MY, Cohen RC. A Scalable Calibration Method for Enhanced Accuracy in Dense Air Quality Monitoring Networks. Environmental Science & Technology. 2025;59(5):2599-2610. doi:10.1021/acs.est.4c08855

BibTeX
@article{Winter2025,
  author = {Winter, Anna R and Zhu, Yishu and Asimow, Naomi G and Patel, Milan Y and Cohen, Ronald C},
  title = {A Scalable Calibration Method for Enhanced Accuracy in Dense Air Quality Monitoring Networks},
  journal = {Environmental Science & Technology},
  year = {2025},
  volume = {59},
  number = {5},
  pages = {2599--2610},
  doi = {10.1021/acs.est.4c08855}
}