EUVIMEDScopri EUVIMED
Crossref

Calibration and Application of PUF Disk Passive Air Samplers To Assess Chlorinated Paraffins in Ambient Air in Australia, China, and Vietnam

Chang He iD, Phong K Thai iD, Lidwina Bertrand, Ayomi Jayarathne, Louise van Mourik iD, Dam Hoang Phuc, Andrew Banks, Jochen F Mueller, Xianyu Fisher Wang iD

Environmental Science & Technology · 2023

DOI: 10.1021/acs.est.3c06703 ↗

At a glance

Journal article in Environmental Science & Technology, 2023. Written by Chang He and 8 co-authors. Institution: Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk …. Major MEDLINE topics: Hydrocarbons, Chlorinated. Cited 14 times so far (Crossref); 65 references. Funded by: AXA Research Fund, National Health and Medical Research Council, Australian Research Council.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Ambient air samples were collected in Brisbane (Australia), Dalian (China), and Hanoi (Vietnam) during Mar 2013-Feb 2018 using polyurethane foam based passive air samplers. A sampling rate calibration experiment was conducted for chlorinated paraffins (CPs, i.e., short-chain, medium-chain, and long-chain CPs), where the sampling rates were 4.5 ± 0.7, 4.8 ± 0.3, and 4.8 ± 2.1 m3 day-1 for SCCPs, MCCPs, and LCCPs, respectively. The atmospheric concentration of CPs was then calculated and the medians of ∑CPs were 0.079, 1.0, and 0.89 ng m-3 in Brisbane, Dalian, and Hanoi, respectively. The concentration of CPs in Brisbane's air remained at low levels, with no significant differences observed between the city background site and the city center site, indicating limited usage and production of CPs in this city. The highest concentration of MCCPs was detected in Dalian, while the highest concentration of SCCPs was detected in Hanoi. A decrease of SCCP concentration and an increase of MCCPs' were found in Brisbane's air from 2016 to 2018, while increasing trends for both SCCPs and MCCPs were observed in Dalian. These results indicated impacts from different sources of CPs in the investigated cities.

Subjects

MeSH terms (MEDLINE)

Hydrocarbons, ChlorinatedParaffinVietnamCalibrationEnvironmental MonitoringChinaAustralia

Author keywords

atmospherechlorinated paraffinsflame retardantspolyurethane foamsampling rate

Substances

Hydrocarbons, ChlorinatedParaffin

Authors and institutions

  • Guangdong-Hong Kong-Macao Joint Laboratory for Contaminants Exposure and Health, Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, Institute of Environmental Health and Pollution Control, Guan…
  • Guangzhou Key Laboratory of Environmental Catalysis and Pollution Control, Key Laboratory for City Cluster Environmental Safety and Green Development of the Ministry of Education, School of Environmental Science and Eng…
  • QAEHS, Queensland Alliance for Environmental Health Sciences, The University of Queensland, 4102 Brisbane, Australia.
  • CIBICI- CONICET and Universidad Nacional de Córdoba, Facultad Ciencias Químicas, Dpto. Bioquímica Clínica, 5000 Córdoba, Argentina.
  • Department of Environment and Health, Vrije Universiteit, De Boelelaan 1087, 1081 HV Amsterdam, The Netherlands.
  • Hanoi University of Science and Technology, Hanoi 10999, Viet Nam.

ORCID profiles: Chang He, Phong K Thai, Louise van Mourik, Xianyu Fisher Wang

Funding

  • AXA Research Fund
  • National Health and Medical Research Council
  • Australian Research Council
  • Minderoo Foundation
  • Australian Government
  • Fondo para la Investigaci?n Cient?fica y Tecnol?gica

Cite

APA

He, C., Thai, P. K., Bertrand, L., Jayarathne, A., van Mourik, L., Phuc, D. H., Banks, A., Mueller, J. F., & Wang, X. F. (2023). Calibration and Application of PUF Disk Passive Air Samplers To Assess Chlorinated Paraffins in Ambient Air in Australia, China, and Vietnam. Environmental Science & Technology. https://doi.org/10.1021/acs.est.3c06703

Vancouver

He C, Thai PK, Bertrand L, Jayarathne A, van Mourik L, Phuc DH, et al. Calibration and Application of PUF Disk Passive Air Samplers To Assess Chlorinated Paraffins in Ambient Air in Australia, China, and Vietnam. Environmental Science & Technology. 2023. doi:10.1021/acs.est.3c06703

BibTeX
@article{He2023,
  author = {He, Chang and Thai, Phong K and Bertrand, Lidwina and Jayarathne, Ayomi and van Mourik, Louise and Phuc, Dam Hoang and Banks, Andrew and Mueller, Jochen F and Wang, Xianyu Fisher},
  title = {Calibration and Application of PUF Disk Passive Air Samplers To Assess Chlorinated Paraffins in Ambient Air in Australia, China, and Vietnam},
  journal = {Environmental Science & Technology},
  year = {2023},
  doi = {10.1021/acs.est.3c06703}
}
Start for free →