EUVIMEDOpdag EUVIMED
StudienprotokollOpen access · CC BY-NC-ND 4.0

Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol

Clay Bell iD, Chiemezie Ilonze iD, Aidan Duggan iD, Daniel Zimmerle iD

Environmental Science & Technology · 2023

DOI: 10.1021/acs.est.2c09235 ↗

At a glance

Studienprotokoll in Environmental Science & Technology, 2023. Written by Clay Bell and 3 co-authors. Institution: Energy Institute, Colorado State University, Fort Collins, Colorado 80524, United States. Major MEDLINE topics: Air Pollutants, Environmental Monitoring. Cited 65 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Office of Fossil Energy.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Continuous emission monitoring (CM) solutions promise to detect large fugitive methane emissions in natural gas infrastructure sooner than traditional leak surveys, and quantification by CM solutions has been proposed as the foundation of measurement-based inventories. This study performed single-blind testing at a controlled release facility (release from 0.4 to 6400 g CH4/h) replicating conditions that were challenging, but less complex than typical field conditions. Eleven solutions were tested, including point sensor networks and scanning/imaging solutions. Results indicated a 90% probability of detection (POD) of 3-30 kg CH4/h; 6 of 11 solutions achieved a POD 50%. False positive rates ranged from 0 to 79%. Six solutions estimated emission rates. For a release rate of 0.1-1 kg/h, the solutions' mean relative errors ranged from -44% to +586% with single estimates between -97% and +2077%, and 4 solutions' upper uncertainty exceeding +900%. Above 1 kg/h, mean relative error was -40% to +93%, with two solutions within ±20%, and single-estimate relative errors were from -82% to +448%. The large variability in performance between CM solutions, coupled with highly uncertain detection, detection limit, and quantification results, indicates that the performance of individual CM solutions should be well understood before relying on results for internal emissions mitigation programs or regulatory reporting.

Subjects

MeSH terms (MEDLINE)

Air PollutantsEnvironmental MonitoringMethaneNatural GasSingle-Blind Method

Author keywords

Methanedetection limitemissions mitigationemissions quantificationnatural gassource attribution

Substances

Air PollutantsMethaneNatural Gas

Authors and institutions

  • Energy Institute, Colorado State University, Fort Collins, Colorado 80524, United States.
  • BPX Energy, Denver, Colorado 80202, United States.
  • Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States.

ORCID profiles: Clay Bell, Chiemezie Ilonze, Aidan Duggan, Daniel Zimmerle

Funding

  • Office of Fossil Energy

Cite

APA

Bell, C., Ilonze, C., Duggan, A., & Zimmerle, D. (2023). Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol. Environmental Science & Technology. https://doi.org/10.1021/acs.est.2c09235

Vancouver

Bell C, Ilonze C, Duggan A, Zimmerle D. Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol. Environmental Science & Technology. 2023. doi:10.1021/acs.est.2c09235

BibTeX
@article{Bell2023,
  author = {Bell, Clay and Ilonze, Chiemezie and Duggan, Aidan and Zimmerle, Daniel},
  title = {Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol},
  journal = {Environmental Science & Technology},
  year = {2023},
  doi = {10.1021/acs.est.2c09235}
}
Start for free →