Ecotoxicity Evaluation of Fire-Extinguishing Water from Large-Scale Battery and Battery Electric Vehicle Fire Tests
Environmental Science & Technology · 2023-03-28 · 57 (12) · 4821-4830
DOI: 10.1021/acs.est.2c08581 ↗At a glance
Journal article in Environmental Science & Technology, published online on 2023-03-13. Written by Maria Quant and 3 co-authors. Institution: Department of Fire and Safety, RISE Research Institutes of Sweden, Brinellgatan 4, 501 15 Borås, Sweden. Major MEDLINE topics: Fires, Fluorocarbons. Cited 58 times so far (Crossref); 61 references. The full text is freely available (open access, CC BY 4.0). Funded by: Myndigheten f?r Samh?llsskydd och Beredskap, Energimyndigheten, Stena Teknik.
Abstract (original language)
Electrified transport has multiple benefits but has also raised some concerns, for example, the flammable formulations used in lithium-ion batteries. Fires in traction batteries can be difficult to extinguish because the battery cells are well protected and hard to reach. To control the fire, firefighters must prolong the application of extinguishing media. In this work, extinguishing water from three vehicles and one battery pack fire test were analyzed for inorganic and organic pollutants, including particle-bound polycyclic aromatic hydrocarbons and soot content. Additionally, the acute toxicity of the collected extinguishing water on three aquatic species was determined. The vehicles used in the fire tests were both conventional petrol-fueled and battery electric. For all of the tests, the analysis of the extinguishing water showed high toxicity toward the tested aquatic species. Several metals and ions were found in concentrations above the corresponding surface water guideline values. Per- and polyfluoroalkyl substances were detected in concentrations ranging between 200 and 1400 ng L-1. Flushing the battery increased the concentration of per- and polyfluoroalkyl substances to 4700 ng L-1. Extinguishing water from the battery electric vehicle and the battery pack contained a higher concentration of nickel, cobalt, lithium, manganese, and fluoride compared with the water samples analyzed from the conventional vehicle.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Fire and Safety, RISE Research Institutes of Sweden, Brinellgatan 4, 501 15 Borås, Sweden.
ORCID profiles: Jonna Hynynen
Funding
- Myndigheten f?r Samh?llsskydd och Beredskap
- Energimyndigheten
- Stena Teknik
- ColdCut systems
- Bor?s Bildemontering
- L?nsf?rs?kringar G?teborg and Bohusl?n
- If Skadef?rs?kring
- L?nsf?rs?kringar ?lvsborg
Cite
APA
Quant, M., Willstrand, O., Mallin, T., & Hynynen, J. (2023). Ecotoxicity Evaluation of Fire-Extinguishing Water from Large-Scale Battery and Battery Electric Vehicle Fire Tests. Environmental Science & Technology, 57(12), 4821-4830. https://doi.org/10.1021/acs.est.2c08581
Vancouver
Quant M, Willstrand O, Mallin T, Hynynen J. Ecotoxicity Evaluation of Fire-Extinguishing Water from Large-Scale Battery and Battery Electric Vehicle Fire Tests. Environmental Science & Technology. 2023;57(12):4821-4830. doi:10.1021/acs.est.2c08581
BibTeX
@article{Quant2023,
author = {Quant, Maria and Willstrand, Ola and Mallin, Tove and Hynynen, Jonna},
title = {Ecotoxicity Evaluation of Fire-Extinguishing Water from Large-Scale Battery and Battery Electric Vehicle Fire Tests},
journal = {Environmental Science & Technology},
year = {2023},
volume = {57},
number = {12},
pages = {4821--4830},
doi = {10.1021/acs.est.2c08581}
}
EUVIMED