EUVIMEDEUVIMED entdecken
Crossref

Sustainable and Reagentless Fenton Treatment of Complex Wastewater

Guan Wang, Kai Tang, Adam C Hambly, Yifeng Zhang iD, Henrik Rasmus Andersen

Environmental Science & Technology · 10.01.2023 · 57 (1) · 626-634

DOI: 10.1021/acs.est.2c06702 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 13.12.2022. Verfasst von Guan Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark. Hauptthemen laut MEDLINE: Wastewater, Water Pollutants, Chemical. Die Arbeit wurde bisher 48-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Carlsbergfondet, Guangzhou Elite Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional Fenton treatment is fundamentally impractical for large-scale applications, as the consumption of Fe(II), H2O2, and pH regulators and the accumulation of iron hydroxide sludge are very costly. This paper describes a new method for Fenton treatment of complex wastewater without additional dosing of Fe(II) and H2O2, without iron-sludge accumulation, and with less consumption of pH regulators, using a novel bioelectrode system. Our new system includes a novel three-chamber microbial electrolysis unit and Fenton reaction unit, where Fenton reagents are generated by biotic and abiotic cathodes, while the bioanode simultaneously degrades biodegradable organics from the wastewater. The system's self-alkalinity buffering also waives the need for pH regulators. Dissolved organic carbon and 22 specific recalcitrant organics were removed by 99% and between 78 and 100%, respectively. The bioelectrode system generated 13 ± 3 mg/L dissolved Fe(II) and 5 ± 0.4 mg/L H2O2 for the Fenton reaction unit. The closed iron cycle avoided iron loss and iron sludge accumulation during operation. The pH regulator dosage and operating costs were just 9.7 and 1.4%, respectively, of what is required by classic Fenton. The low operating cost and reduction in chemical usage make it an efficient, sustainable alternative to the conventional treatment processes currently used for complex wastewater.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterWater Pollutants, ChemicalSewageHydrogen PeroxideOxidation-ReductionIronFerrous CompoundsWaste Disposal, Fluid

Stichwörter der Autor:innen

Fenton oxidationiron cyclerecyclingsustainabilitywaste-to-resource

Substanzen

WastewaterSewageHydrogen PeroxideIronFerrous CompoundsWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Environmental and Resource Engineering, Technical University of Denmark, DK-2800Lyngby, Denmark.

ORCID-Profile: Yifeng Zhang

Förderung

  • Carlsbergfondet
  • Guangzhou Elite Project

Zitieren

APA

Wang, G., Tang, K., Hambly, A. C., Zhang, Y., & Andersen, H. R. (2023). Sustainable and Reagentless Fenton Treatment of Complex Wastewater. Environmental Science & Technology, 57(1), 626-634. https://doi.org/10.1021/acs.est.2c06702

Vancouver

Wang G, Tang K, Hambly AC, Zhang Y, Andersen HR. Sustainable and Reagentless Fenton Treatment of Complex Wastewater. Environmental Science & Technology. 2023;57(1):626-634. doi:10.1021/acs.est.2c06702

BibTeX
@article{Wang2023,
  author = {Wang, Guan and Tang, Kai and Hambly, Adam C and Zhang, Yifeng and Andersen, Henrik Rasmus},
  title = {Sustainable and Reagentless Fenton Treatment of Complex Wastewater},
  journal = {Environmental Science & Technology},
  year = {2023},
  volume = {57},
  number = {1},
  pages = {626--634},
  doi = {10.1021/acs.est.2c06702}
}
Kostenlos starten →