Revisiting Disinfection Byproducts with Supercritical Fluid Chromatography-High Resolution-Mass Spectrometry: Identification of Novel Halogenated Sulfonic Acids in Disinfected Drinking Water
Environmental Science & Technology · 2023-03-07 · 57 (9) · 3527-3537
DOI: 10.1021/acs.est.2c05536 ↗At a glance
Journal article in Environmental Science & Technology, published online on 2023-02-20. Written by Maolida Nihemaiti and 3 co-authors. Institution: Department of Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstrasse 15, 04318 Leipzig, Germany. Major MEDLINE topics: Disinfectants, Drinking Water, Chromatography, Supercritical Fluid, Water Pollutants, Chemical. Cited 32 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY 4.0). Funded by: Bundesministerium f?r Bildung und Forschung.
Abstract (original language)
High resolution mass spectrometry (HRMS) coupled to either gas chromatography or reversed-phase liquid chromatography is the generic method to identify unknown disinfection byproducts (DBPs) but can easily overlook their highly polar fractions. In this study, we applied an alternative chromatographic separation method, supercritical fluid chromatography-HRMS, to characterize DBPs in disinfected water. In total, 15 DBPs were tentatively identified for the first time as haloacetonitrilesulfonic acids, haloacetamidesulfonic acids, and haloacetaldehydesulfonic acids. Cysteine, glutathione, and p-phenolsulfonic acid were found as precursors during lab-scale chlorination, with cysteine providing the highest yield. A mixture of the labeled analogues of these DBPs was prepared by chlorination of 13C3-15N-cysteine and analyzed using nuclear magnetic resonance spectroscopy for structural confirmation and quantification. A total of 6 drinking water treatment plants utilizing various source waters and treatment trains produced sulfonated DBPs upon disinfection. Those were widespread in the tap water of 8 cities across Europe, with estimated concentrations up to 50 and 800 ng/L for total haloacetonitrilesulfonic acids and haloacetaldehydesulfonic acids, respectively. Up to 850 ng/L haloacetonitrilesulfonic acids were found in 3 public swimming pools. Considering the stronger toxicity of haloacetonitriles, haloacetamides, and haloacetaldehydes than the regulated DBPs, these newly found sulfonic acid derivatives may also pose a health risk.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Analytical Chemistry, Helmholtz Centre for Environmental Research - UFZ, Permoserstrasse 15, 04318 Leipzig, Germany.
- Institute of Organic Chemistry, University of Leipzig, Johannisallee 29, 04103 Leipzig, Germany.
- Institute of Analytical Chemistry, University of Leipzig, Linnéstrasse 3, 04103 Leipzig, Germany.
ORCID profiles: Maolida Nihemaiti, Thorsten Reemtsma
Funding
- Bundesministerium f?r Bildung und Forschung
Cite
APA
Nihemaiti, M., Icker, M., Seiwert, B., & Reemtsma, T. (2023). Revisiting Disinfection Byproducts with Supercritical Fluid Chromatography-High Resolution-Mass Spectrometry: Identification of Novel Halogenated Sulfonic Acids in Disinfected Drinking Water. Environmental Science & Technology, 57(9), 3527-3537. https://doi.org/10.1021/acs.est.2c05536
Vancouver
Nihemaiti M, Icker M, Seiwert B, Reemtsma T. Revisiting Disinfection Byproducts with Supercritical Fluid Chromatography-High Resolution-Mass Spectrometry: Identification of Novel Halogenated Sulfonic Acids in Disinfected Drinking Water. Environmental Science & Technology. 2023;57(9):3527-3537. doi:10.1021/acs.est.2c05536
BibTeX
@article{Nihemaiti2023,
author = {Nihemaiti, Maolida and Icker, Maik and Seiwert, Bettina and Reemtsma, Thorsten},
title = {Revisiting Disinfection Byproducts with Supercritical Fluid Chromatography-High Resolution-Mass Spectrometry: Identification of Novel Halogenated Sulfonic Acids in Disinfected Drinking Water},
journal = {Environmental Science & Technology},
year = {2023},
volume = {57},
number = {9},
pages = {3527--3537},
doi = {10.1021/acs.est.2c05536}
}
EUVIMED