EUVIMEDEUVIMED entdecken
Crossref

Near-Infrared Fluorescent Turn-On Probe for Selective Detection of Hypochlorite in Aqueous Medium and Live Cell Imaging

Anwesha Maiti, Saikat Kumar Manna iD, Satyajit Halder iD, Rajdeep Ganguly iD, Anirban Karak, Pintu Ghosh, Kuladip Jana iD, Ajit Kumar Mahapatra iD

Chemical Research in Toxicology · 2024

DOI: 10.1021/acs.chemrestox.4c00222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemical Research in Toxicology, 2024. Verfasst von Anwesha Maiti und 7 weiteren Autor:innen. Beteiligte Einrichtung: Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah, Sh…. Hauptthemen laut MEDLINE: Hypochlorous Acid, Fluorescent Dyes. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: Council of Scientific and Industrial Research, India, Science and Engineering Research Board.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hypochlorite, as an important reactive oxygen species (ROS), plays a vital role in many physiological and pathological processes, but an excess concentration of hypochlorite (ClO-) may become toxic to humans and cause disease. Hence, the selective and rapid detection of hypochlorite (ClO-) is necessary for human safety. Here, we report a novel near-infrared (NIR) fluorescence "turn-on" and highly selective benzophenoxazinium chloride-based fluorescent probe, BPH (benzophenoxazinium dihydroxy benzaldehyde), for hypochlorite detection. Due to hypochlorite-induced vicinal diol oxidation to the corresponding ortho benzoquinone derivative, the photoinduced electron transfer (PET) process, which was operating from vicinal diol to the benzophenoxazinium chloride receptor moiety, was suddenly inhibited, as a result of which strong NIR fluorescence "turn-on" emission was observed. The detection limit of BPH was found to be 2.39 × 10-10 M, or 0.23 nM. BPH was successfully applied for exogenous and endogenous hypochlorite detection in live MDA-MB 231 cells.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypochlorous AcidFluorescent DyesHumansInfrared RaysWaterOptical ImagingMolecular StructureCell SurvivalBenzaldehydes

Substanzen

Hypochlorous AcidFluorescent DyesWaterBenzaldehydes

Autor:innen und Institutionen

  • Molecular Sensor and Supramolecular Chemistry Laboratory, Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah, Shibpur, West Bengal 711103, India.
  • Department of Chemistry, Haldia Government College, Haldia, Purba Medinipur, Debhog, West Bengal 721657, India.
  • Division of Molecular Medicine, Bose Institute, P 1/12, CIT Scheme VIIM, Kolkata 700054, India.
  • Centre for Healthcare Science and Technology, Indian Institute of Engineering Science and Technology, Shibpur 711103, India.

ORCID-Profile: Saikat Kumar Manna, Satyajit Halder, Rajdeep Ganguly, Kuladip Jana, Ajit Kumar Mahapatra

Förderung

  • Council of Scientific and Industrial Research, India
  • Science and Engineering Research Board

Zitieren

APA

Maiti, A., Manna, S. K., Halder, S., Ganguly, R., Karak, A., Ghosh, P., Jana, K., & Mahapatra, A. K. (2024). Near-Infrared Fluorescent Turn-On Probe for Selective Detection of Hypochlorite in Aqueous Medium and Live Cell Imaging. Chemical Research in Toxicology. https://doi.org/10.1021/acs.chemrestox.4c00222

Vancouver

Maiti A, Manna SK, Halder S, Ganguly R, Karak A, Ghosh P, et al. Near-Infrared Fluorescent Turn-On Probe for Selective Detection of Hypochlorite in Aqueous Medium and Live Cell Imaging. Chemical Research in Toxicology. 2024. doi:10.1021/acs.chemrestox.4c00222

BibTeX
@article{Maiti2024,
  author = {Maiti, Anwesha and Manna, Saikat Kumar and Halder, Satyajit and Ganguly, Rajdeep and Karak, Anirban and Ghosh, Pintu and Jana, Kuladip and Mahapatra, Ajit Kumar},
  title = {Near-Infrared Fluorescent Turn-On Probe for Selective Detection of Hypochlorite in Aqueous Medium and Live Cell Imaging},
  journal = {Chemical Research in Toxicology},
  year = {2024},
  doi = {10.1021/acs.chemrestox.4c00222}
}
Kostenlos starten →