Biological evaluation of a new highly sensitive and selective fluorescent probe for hypochlorous acid and its imaging application in cell and zebrafish
Bioorganic Chemistry · 2025
DOI: 10.1016/j.bioorg.2025.108358 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioorganic Chemistry, 2025. Verfasst von Min Zheng und 11 weiteren Autor:innen. Beteiligte Einrichtung: Biology Institute, Bioengineering Department, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250103, China. Hauptthemen laut MEDLINE: Hypochlorous Acid, Zebrafish, Fluorescent Dyes, Optical Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Department of Science and Technology of Shandong Province, Qilu University of Technology, Shandong Academy of Sciences.
Abstract (Originalsprache)
Hypochlorous acid is one of the most widely distributed reactive oxygen species in vivo. It is usually used as a signal molecule to participate in various life activities such as immunity and metabolism, and plays a notable role in maintaining homeostasis. When hypochlorous acid level is abnormal in the body, it will lead to a variety of diseases, such as Parkinson's disease, Alzheimer's disease, atherosclerosis and cancer. Therefore, it is necessary to develop a bio-friendly fluorescent probe with fast sensitivity and specific accuracy. In this study, the innovative probe PRS owns good optical properties, sensitivity and selectivity, and the response mechanism that the generation of new bond enhanced the fluorescence intensity is studied. Biocompatibility of probe is systematically and innovatively evaluated by using cells and zebrafish models. Note that the biocompatibility valuation of probe results from cytotoxicity test, zebrafish behavioral test, hepatotoxicity test, cardiotoxicity test, nephrotoxicity test, blood vessel toxicity test, immunotoxicity test and neurotoxicity test, and experimental indicators like swimming duration, swimming distance, swimming speed, pericardial rub, fractional shortening, stroke volume, heart rate, SV-BA, shortening rate of the ventricular short axis, liver area, liver fluorescence intensity, total length of intersegmental vessels, number of vessels, and average vessel length show that the probe has good biocompatibility. Moreover, the detection performance of the probe shows that the probe can target hypochlorous acid in cell and zebrafish models. The probe is proved to be much essential for the monitoring of hypochlorous acid in vivo. Therefore, it has been proven that the meaningful detection of probe PRS for HOCl is promising in the living organism. Moreover, our innovative biocompatibility testing can be used to evaluate the biosafety of fluorescent probe as well.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biology Institute, Bioengineering Department, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250103, China.
- School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China.
- Biology Institute, Bioengineering Department, Qilu University of Technology (Shandong Academy of Sciences), Jinan 250103, China. Electronic address: shengwenlong1121@163.com.
Förderung
- Department of Science and Technology of Shandong Province
- Qilu University of Technology
- Shandong Academy of Sciences
- NSFC
- Natural Science Foundation of Shandong Province
- Jinan Science and Technology Bureau
- Major Scientific and Technological Innovation Project of Shandong Province
Zitieren
APA
Zheng, M., Wen, H., Meng, Z., Guo, W., Wang, K., Yu, M., Li, K., Zhang, Y., Liu, K., Cai, L., Zhu, B., & Sheng, W. (2025). Biological evaluation of a new highly sensitive and selective fluorescent probe for hypochlorous acid and its imaging application in cell and zebrafish. Bioorganic Chemistry. https://doi.org/10.1016/j.bioorg.2025.108358
Vancouver
Zheng M, Wen H, Meng Z, Guo W, Wang K, Yu M, et al. Biological evaluation of a new highly sensitive and selective fluorescent probe for hypochlorous acid and its imaging application in cell and zebrafish. Bioorganic Chemistry. 2025. doi:10.1016/j.bioorg.2025.108358
BibTeX
@article{Zheng2025,
author = {Zheng, Min and Wen, Huayan and Meng, Zhengxiang and Guo, Wenli and Wang, Kun and Yu, Miaohui and Li, Ke and Zhang, Yun and Liu, Kechun and Cai, Lei and Zhu, Baocun and Sheng, Wenlong},
title = {Biological evaluation of a new highly sensitive and selective fluorescent probe for hypochlorous acid and its imaging application in cell and zebrafish},
journal = {Bioorganic Chemistry},
year = {2025},
doi = {10.1016/j.bioorg.2025.108358}
}
EUVIMED