EUVIMEDEUVIMED entdecken
Crossref

Application of Numerical Experimental Design in Consequence Analysis of Chlorine Release Using Breeze Incident Analyst Software

Paulin Pah Yen Ling, Mohamad Syazarudin Md Said

ACS Chemical Health & Safety · 22.09.2025 · 32 (5) · 582-599

DOI: 10.1021/acs.chas.5c00026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Chemical Health & Safety, online erschienen am 29.08.2025. Verfasst von Paulin Pah Yen Ling und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although various studies have applied numerical experimental design and response surface methodology (RSM) in combination with consequence modeling tools for gas dispersion prediction, there remains a need for a more generalizable and robust approach. Such an approach should account for diverse industrial settings, both offshore and onshore, and variable environmental conditions including atmospheric parameters, wind, and topography. This study integrates numerical experimental design with BREEZE Incident Analyst software to model chlorine gas dispersion in an industrial environment. The effects of five independent variables, which are wind speed, leakage hole diameter, release height, ambient temperature, and surface roughness, on the downwind distance to a specific toxic threshold level were investigated. Significant interactions were identified, while the release height was found to have a minimal influence on gas dispersion. Well-validated predictive models were developed using RSM, followed by optimization to identify the worst-case scenario, defined as the maximum downwind distance to the ERPG-2 level (3 ppm for chlorine). The optimization results indicated that the worst-case scenario occurs under conditions of 1.5 m/s wind speed, 0.076 m leakage diameter, 38 °C ambient temperature, and urban surface roughness. This study demonstrates the effectiveness of integrating numerical experimental design with consequence modeling to enhance the accuracy and reliability of gas dispersion predictions while minimizing uncertainties.

Zitieren

APA

Ling, P. P. Y., & Said, M. S. M. (2025). Application of Numerical Experimental Design in Consequence Analysis of Chlorine Release Using Breeze Incident Analyst Software. ACS Chemical Health & Safety, 32(5), 582-599. https://doi.org/10.1021/acs.chas.5c00026

Vancouver

Ling PPY, Said MSM. Application of Numerical Experimental Design in Consequence Analysis of Chlorine Release Using Breeze Incident Analyst Software. ACS Chemical Health & Safety. 2025;32(5):582-599. doi:10.1021/acs.chas.5c00026

BibTeX
@article{Ling2025,
  author = {Ling, Paulin Pah Yen and Said, Mohamad Syazarudin Md},
  title = {Application of Numerical Experimental Design in Consequence Analysis of Chlorine Release Using Breeze Incident Analyst Software},