Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants
Analytical Chemistry · 10.11.2026 · 98 (44) · 31678-31691
DOI: 10.1021/acs.analchem.6c05525 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 12.10.2026. Verfasst von Zhijin Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Chongqing Key Laboratory for Pharmaceutical Metabolism Research, College of Pharmacy, Chongqing Medical University, Chongqing400016, P. R. China. Hauptthemen laut MEDLINE: Polymorphism, Single Nucleotide, Nucleic Acid Amplification Techniques, DNA. Die Arbeit nennt 33 Literaturangaben. Gefördert von: Natural Science Foundation of Chongqing, National Natural Science Foundation of China (NSFC).
Abstract (Originalsprache)
Sensitive detection of low-abundance single-nucleotide variants (SNVs) remains challenging because rare mutant alleles are frequently masked by overwhelming wild-type DNA backgrounds. Herein, we develop a photo-programmable temporally uncoupled one-pot isothermal sensing platform (PTU-One-Pot) for sensitive enrichment and detection of the EGFR L858R mutation. The platform integrates restriction endonuclease-mediated wild-type DNA digestion with recombinase polymerase amplification (RPA) in a closed tube. To resolve the intrinsic kinetic conflict between relatively slow wild-type DNA digestion and rapid RPA amplification, RPA primers are modified with a photocleavable 6-nitropiperonyloxymethyl (NPOM) group. During the initial phase, NPOM-caged primers suppress RPA amplification, allowing MlsI restriction endonuclease to selectively digest wild-type templates. Subsequent brief ultraviolet irradiation removes the NPOM protection and activates RPA amplification of remaining mutant-type templates. Mechanistic studies confirm RPA photo-programmable trigger and sequence-selective wild-type template cleavage. Droplet digital PCR, high-resolution melting, Sanger sequencing verify that PTU-One-Pot can effectively eliminate wild-type templates and convert the final products from wild-type-dominated to mutant-enriched. Under optimized conditions, fluorescence readout achieves a limit of detection of 0.05% variant allele frequency, showing high specificity to EGFR L858R mutation. Lateral flow assay integration enables low-instrument visual detection at 1% variant allele frequency. Evaluation using 23 formalin-fixed paraffin-embedded patient samples demonstrates that both fluorescence and lateral flow readouts are consistent with next-generation sequencing and droplet digital PCR reference results. Overall, this PTU-One-Pot strategy provides a rapid and sensitive isothermal platform for low-abundance mutation enrichment and analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Chongqing Key Laboratory for Pharmaceutical Metabolism Research, College of Pharmacy, Chongqing Medical University, Chongqing400016, P. R. China.
Förderung
- Natural Science Foundation of Chongqing
- National Natural Science Foundation of China (NSFC)
Zitieren
APA
Li, Z., Qing, M., Wang, J., & Yu, C. (2026). Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants. Analytical Chemistry, 98(44), 31678-31691. https://doi.org/10.1021/acs.analchem.6c05525
Vancouver
Li Z, Qing M, Wang J, Yu C. Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants. Analytical Chemistry. 2026;98(44):31678-31691. doi:10.1021/acs.analchem.6c05525
BibTeX
@article{Li2026,
author = {Li, Zhijin and Qing, Min and Wang, Jianbo and Yu, Chao},
title = {Photo-Programmable Temporal Uncoupling Enables One-Pot Isothermal Enrichment and Detection of Low-Abundance Single-Nucleotide Variants},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {44},
pages = {31678--31691},
doi = {10.1021/acs.analchem.6c05525}
}
EUVIMED