EUVIMEDEUVIMED entdecken
Crossref

A FEN1-EDCR dual-amplification strategy for ultrasensitive detection of CHCHD10 c.176C>T mutation

Han Pan, Murilege Chao, Miao He, Jinhua Chen, Feifan Yin, Yongliang Cai, Wenting Cheng, Zhongyun Wang, Yang Xiang

Biosensors and Bioelectronics · 2026-05 · 300 · 118468

DOI: 10.1016/j.bios.2026.118468 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-05. Verfasst von Han Pan und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, PR China. Hauptthemen laut MEDLINE: Flap Endonucleases, Biosensing Techniques, Mitochondrial Proteins. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, State Key Laboratory of Natural and Biomimetic Drugs, Natural Science Foundation of Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A single-base mutation in the CHCHD10 gene can impair thermogenic responses, and inhibit the efficient conversion of white adipose tissue to beige adipose tissue. However, achieving high-fidelity detection of such low-abundance single nucleotide polymorphisms (SNPs) within complex biological matrices remains a critical technological challenge. This study developed a novel method for detecting a single-base mutation in CHCHD10 by integrating the specific recognition of flap endonuclease 1 (FEN1) with the cascade amplification of an entropy-driven circuit reaction (EDCR), supplemented with magnetic separation to suppress background interference. In this process, the mutant target (MT) hybridizes with the upstream probe (UP) and a hairpin downstream probe (DP) to form a specific three-base overlapping structure. FEN1 recognizes and cleaves this structure, releasing a cleavage sequence (CS). Following magnetic purification, the CS activates the EDCR, enabling dual-signal amplification. The hairpin DP design effectively conceals the CS, significantly reducing background noise. The method achieves a detection limit of 0.23 pM, discriminates mutation abundances as low as 0.01% in mixed DNA samples, and demonstrates robust performance in complex matrices such as human serum and high-background genomic DNA. This work provides an innovative and reliable methodological tool for the detection of low-abundance point mutations in complex samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flap EndonucleasesBiosensing TechniquesMitochondrial ProteinsHumansPolymorphism, Single NucleotidePoint MutationLimit of DetectionNucleic Acid Amplification TechniquesDNA Mutational AnalysisDNA

Stichwörter der Autor:innen

BiosensorCHCHD10Entropy-driven circuit reaction (EDCR)FEN1Low-abundance mutationPoint mutation detection

Substanzen

Flap EndonucleasesFEN1 protein, humanMitochondrial ProteinsDNA

Autor:innen und Institutionen

  • State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, PR China.
  • Department of Anesthesiology and Perioperative Medicine, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, PR China.
  • Department of Anesthesiology and Perioperative Medicine, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, PR China. Electronic address: zywang1970@126.com.
  • State Key Laboratory of Pharmaceutical Biotechnology, School of Life Sciences, Nanjing University, Nanjing, 210023, PR China. Electronic address: xiangy@nju.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • State Key Laboratory of Natural and Biomimetic Drugs
  • Natural Science Foundation of Jiangsu Province

Zitieren

APA

Pan, H., Chao, M., He, M., Chen, J., Yin, F., Cai, Y., Cheng, W., Wang, Z., & Xiang, Y. (2026). A FEN1-EDCR dual-amplification strategy for ultrasensitive detection of CHCHD10 c.176C>T mutation. Biosensors and Bioelectronics, 300, 118468. https://doi.org/10.1016/j.bios.2026.118468

Vancouver

Pan H, Chao M, He M, Chen J, Yin F, Cai Y, et al. A FEN1-EDCR dual-amplification strategy for ultrasensitive detection of CHCHD10 c.176C>T mutation. Biosensors and Bioelectronics. 2026;300:118468. doi:10.1016/j.bios.2026.118468

BibTeX
@article{Pan2026,
  author = {Pan, Han and Chao, Murilege and He, Miao and Chen, Jinhua and Yin, Feifan and Cai, Yongliang and Cheng, Wenting and Wang, Zhongyun and Xiang, Yang},
  title = {A FEN1-EDCR dual-amplification strategy for ultrasensitive detection of CHCHD10 c.176C>T mutation},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {300},
  pages = {118468},
  doi = {10.1016/j.bios.2026.118468}
}
Kostenlos starten →