EUVIMEDEUVIMED entdecken
Crossref

Self-Assembled Peptide Hydrogel-Engineered Au/SCN/PCN-222 Photocathode for Antifouling Photoelectrochemical Immunoassay of S100B

Feng Xu, Yao Xiao, Gao-Chao Fan iD, Xiliang Luo iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.6c05145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Feng Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao Univ…. Hauptthemen laut MEDLINE: S100 Calcium Binding Protein beta Subunit, Electrochemical Techniques, Peptides, Hydrogels. Die Arbeit nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

S100B is a clinically important biomarker for traumatic brain injury and neurodegenerative diseases, necessitating the development of sensitive and reliable analytical methods for its determination in complex biological fluids susceptible to potential biofouling and electroactive interference. Herein, we report a robust antifouling photoelectrochemical (PEC) immunoassay based on a self-assembled peptide hydrogel-engineered Au/SCN/PCN-222 photocathode for sensitive S100B detection. The Au/SCN/PCN-222 photocathode integrates sulfur-doped carbon nitride (SCN) quantum dots and Au nanoparticles with the porphyrinic metal–organic framework PCN-222, serving as the signal transduction element with enhanced light absorption and improved charge transfer, thereby increasing the cathodic photocurrent response. To address nonspecific adsorption and biofouling, a self-assembled Fmoc-FF-GG-EK-EK-EK peptide hydrogel was engineered on the photocathode surface, forming a highly hydrated, charge-balanced three-dimensional interface that effectively suppresses biofouling while enabling efficient antibody immobilization. Upon specific recognition of S100B, immune complex formation increases interfacial steric hindrance and suppresses charge transfer, resulting in a concentration-dependent decrease in photocurrent. The proposed PEC immunoassay exhibited high sensitivity, excellent antifouling performance, and good selectivity, enabling reliable analysis in complex biological matrices. This work establishes a general peptide hydrogel-based interfacial engineering strategy for antifouling PEC bioanalysis, providing a versatile and robust platform for biomarker detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

S100 Calcium Binding Protein beta SubunitElectrochemical TechniquesPeptidesHydrogelsNitrilesBiofoulingImmunoassayGoldHumansPhotochemical ProcessesElectrodesHydrogel, Polyethylene Glycol DimethacrylateMetal-Organic FrameworksPorphyrins

Substanzen

S100 Calcium Binding Protein beta SubunitGoldPeptidesHydrogelsS100B protein, humanNitrilescyanogenHydrogel, Polyethylene Glycol DimethacrylatePCN-222Metal-Organic Frameworks

Autor:innen und Institutionen

  • Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao266042, China.

ORCID-Profile: Gao-Chao Fan, Xiliang Luo

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province

Zitieren

APA

Xu, F., Xiao, Y., Fan, G. C., & Luo, X. (2026). Self-Assembled Peptide Hydrogel-Engineered Au/SCN/PCN-222 Photocathode for Antifouling Photoelectrochemical Immunoassay of S100B. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c05145

Vancouver

Xu F, Xiao Y, Fan GC, Luo X. Self-Assembled Peptide Hydrogel-Engineered Au/SCN/PCN-222 Photocathode for Antifouling Photoelectrochemical Immunoassay of S100B. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c05145

BibTeX
@article{Xu2026,
  author = {Xu, Feng and Xiao, Yao and Fan, Gao-Chao and Luo, Xiliang},
  title = {Self-Assembled Peptide Hydrogel-Engineered Au/SCN/PCN-222 Photocathode for Antifouling Photoelectrochemical Immunoassay of S100B},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.6c05145}
}
Kostenlos starten →