Fouling-Free electrochemical strategy based on vertically-aligned peptide layer for cardiac troponin I sensitive detection in human serum
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342866 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Xingao Qin und 2 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Pollution Control and Resources Reuse (Tongji University), College of Environmental Science and Engineering, Tongji Universit…. Hauptthemen laut MEDLINE: Troponin I, Electrochemical Techniques, Gold, Metal Nanoparticles. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Cardiac troponin I (CTnI) is demonstrated as one of the most promising disease biomarkers for early diagnosing acute myocardial infarction (AMI). To date, electrochemical immunosensors have been extensively studied in the field of cTnI determination. But highly accurate and sensitive cTnI detection by this method is still a challenge due to non-specific adsorption on electrode interfaces in complex human serum. As a result, it is necessary to develop an antifouling electrochemical immunosensor with high sensitivity for the detection of cTnI. RESULTS: In this work, an antifouling electrochemical immunosensor was constructed based on vertically-aligned peptide layer consisting of Au nanoparticles (AuNPs) and amphiphilic CEAK16 peptide (CEAK16@AuNPs) for sensitive and accurate detection of cTnI in human serum. The vertically-aligned CEAK16@AuNPs interface provided a stable hydration layer originated from attraction of water molecules by amino acids on the hydrophilic side of the CEAK16, which effectively reduced non-specific adsorption and enhanced electron transfer rate. The cTnI immunosensor possessed great analytical performance with a wide range from 1 fg mL-1 to 1 μg mL-1 and a low detection limit of 0.28 fg mL-1 (S/N = 3). Additionally, the proposed CEAK16@AuNPs sensing interface showed excellent long-term antifouling performance and electrochemical activity that preserved 80 % of the initial signal after 20-days exposure in human serum samples. Consequently, the cTnI immunosensor displayed excellent detection accuracy compared to clinical methods and owned good selectivity, stability and reproducibility. SIGNIFICANCE: The development of this strategy provides a versatile tool for accurate quantitative cTnI analysis in real human serum, thus helping to achieve early AMI diagnosis effectively and holding the promising potentials for other immunosensor in disease diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Pollution Control and Resources Reuse (Tongji University), College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China; Shanghai Institute of Pollution Control an…
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
Zitieren
APA
Qin, X., Zhu, X., & Wang, Y. (2024). Fouling-Free electrochemical strategy based on vertically-aligned peptide layer for cardiac troponin I sensitive detection in human serum. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342866
Vancouver
Qin X, Zhu X, Wang Y. Fouling-Free electrochemical strategy based on vertically-aligned peptide layer for cardiac troponin I sensitive detection in human serum. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342866
BibTeX
@article{Qin2024,
author = {Qin, Xingao and Zhu, Xiaoyu and Wang, Ying},
title = {Fouling-Free electrochemical strategy based on vertically-aligned peptide layer for cardiac troponin I sensitive detection in human serum},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342866}
}