EUVIMEDEUVIMED entdecken
Crossref

Click-Chemistry-Enhanced Dynamic Light Scattering Immunoassay for Ultrasensitive GFAP Detection in Traumatic Brain Injury

Weipeng Tong, Hao Fang, Mingjian Yao, Yujia Chen, Shenghang Zhang, Yingying Cao, Xiaolin Huang iD, Yonghua Xiong iD

Analytical Chemistry · 18.08.2026 · 98 (32) · 23383-23389

DOI: 10.1021/acs.analchem.6c03218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 01.08.2026. Verfasst von Weipeng Tong und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang330047, P. R. China. Hauptthemen laut MEDLINE: Glial Fibrillary Acidic Protein, Brain Injuries, Traumatic, Dynamic Light Scattering. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Double Thousand Plan of Jiangxi Province, National Natural Science Foundation of China, State Key Laboratory of Food Science and Resources.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traumatic brain injury (TBI) requires a rapid and objective assessment; however, current diagnostic methodologies are constrained by subjectivity, reliance on imaging techniques, and insufficient sensitivity for the early detection of biomarkers. In this study, we present a click-chemistry-enhanced dynamic light scattering (DLS) immunoassay for the ultrasensitive detection of glial fibrillary acidic protein (GFAP), a clinically significant blood biomarker for brain injury. Unlike conventional DLS immunoassays, which rely on weak antigen–antibody interactions to drive DLS probe aggregation, the proposed approach transforms immunorecognition into a rapid covalent amplification process through click chemistry. A systematic comparison of three click-chemistry-driven aggregation reactions demonstrated that faster association kinetics led to more efficient probe aggregation and stronger signal amplification. On this basis, the optimized inverse electron-demand Diels–Alder reaction (IEDDA)-enhanced DLS immunoassay exhibits the highest sensitivity for GFAP detection, achieving a limit of detection of 210 fg mL–1, which is 109-fold and 348-fold lower than that of conventional DLS immunoassays and ELISA methods, respectively. The detection time of the proposed method was only 26 min. Additionally, the IEDDA-enhanced DLS immunoassay exhibits favorable performance in the analysis of clinical serum samples. In conclusion, this study introduces an effective signal amplification strategy utilizing click chemistry to enhance the sensitivity of DLS immunoassays, thereby providing a promising analytical platform for the rapid assessment of TBI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glial Fibrillary Acidic ProteinBrain Injuries, TraumaticDynamic Light ScatteringImmunoassayHumansClick ChemistryLimit of DetectionBiomarkers

Substanzen

Glial Fibrillary Acidic ProteinBiomarkersGFAP protein, human

Autor:innen und Institutionen

  • State Key Laboratory of Food Science and Resources, Nanchang University, Nanchang330047, P. R. China.
  • School of Food Science and Technology, Nanchang University, Nanchang330047, P. R. China.
  • Biosafety Level 3 Laboratory, Jiangxi Medical Center for Critical Public Health Events, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang330006, P. R. China.
  • Fujian Key Laboratory of Aptamers Technology, Fuzong Clinical Medical College of Fujian Medical University (900th Hospital), Fuzhou350025, P. R. China.
  • Fuzhou University Affiliated Provincial Hospital , Fuzhou350001, P. R. China.

ORCID-Profile: Xiaolin Huang, Yonghua Xiong

Förderung

  • Double Thousand Plan of Jiangxi Province
  • National Natural Science Foundation of China
  • State Key Laboratory of Food Science and Resources
  • Key Research and Development Program of Jiangxi Province
  • Jiangxi GanPo Talent Support Program

Zitieren

APA

Tong, W., Fang, H., Yao, M., Chen, Y., Zhang, S., Cao, Y., Huang, X., & Xiong, Y. (2026). Click-Chemistry-Enhanced Dynamic Light Scattering Immunoassay for Ultrasensitive GFAP Detection in Traumatic Brain Injury. Analytical Chemistry, 98(32), 23383-23389. https://doi.org/10.1021/acs.analchem.6c03218

Vancouver

Tong W, Fang H, Yao M, Chen Y, Zhang S, Cao Y, et al. Click-Chemistry-Enhanced Dynamic Light Scattering Immunoassay for Ultrasensitive GFAP Detection in Traumatic Brain Injury. Analytical Chemistry. 2026;98(32):23383-23389. doi:10.1021/acs.analchem.6c03218

BibTeX
@article{Tong2026,
  author = {Tong, Weipeng and Fang, Hao and Yao, Mingjian and Chen, Yujia and Zhang, Shenghang and Cao, Yingying and Huang, Xiaolin and Xiong, Yonghua},
  title = {Click-Chemistry-Enhanced Dynamic Light Scattering Immunoassay for Ultrasensitive GFAP Detection in Traumatic Brain Injury},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {32},
  pages = {23383--23389},
  doi = {10.1021/acs.analchem.6c03218}
}
Kostenlos starten →