Subpicogram-Level Quantification of Trace Biomarkers Using an Automated High-Sensitivity Chemiluminescence Immunoassay Technology Based on a Novel Substrate Enhancement Strategy
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.6c03190 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Kexin Li und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, State Key Laboratory of Molecular Oncology, National Cancer Center/National Clinical Research Center for Cancer/Ca…. Hauptthemen laut MEDLINE: Luminescent Measurements. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Science and Technology Major Project, Shenzhen Mindray Bio-Medical Electronics Co., Ltd..
Abstract (Originalsprache)
Trace biomarkers showed great potential for improving the diagnosis and monitoring of various diseases. However, the sensitivity of the current high-throughput detection platforms is limited, posing a significant challenge for the reliable measurement and clinical application of trace biomarkers. We developed an automated high-sensitivity chemiluminescence immunoassay (CLIA) technology with subpicogram-level sensitivity based on the modification of the substrate molecular structure and the synergy of surfactant and fluorescein. Using this technology, we constructed assay kits for five trace biomarkers: leukemia inhibitory factor (LIF), high-sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT), phosphorylated tau-217 (p-tau217), and estradiol (E2). The analytical and clinical performance was evaluated by examining the precision, linearity, limits of detection, and methodological comparison. The high-sensitivity chemiluminescent substrate demonstrated approximately 7-fold higher sensitivity and 2.5-fold greater luminescence efficiency compared to those of the traditional substrate, with a linear range exceeding 160 million relative light units (RLUs). The five trace biomarker assays exhibited excellent analytical sensitivity, with the LoD values of 0.070 pg/mL (LIF), 0.18 pg/mL (hs-cTnI), 1.1 pg/mL (hs-cTnT), 0.007 pg/mL (p-tau217), and 0.113 pg/mL (E2 II). Compared with other high-sensitivity detection methods, the Passing–Bablok linear correlation coefficients (r) ranged from 0.9767 to 0.9974. The proportions of cTnI, cTnT, and E2 II concentrations above the LoD in healthy populations exceeded 98%. We established an automated high-sensitivity CLIA technology based on a novel substrate enhancement strategy, improving the analytical sensitivity to the subpicogram level. An automated high-throughput detection method of various trace biomarkers was realized that may have broad application in the clinic.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory, State Key Laboratory of Molecular Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Me…
- Immunoassay Reagent R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd, Shenzhen518055, China.
- Department of Clinical Laboratory, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang310016, China.
- Key Laboratory of Precision Medicine in Diagnosis and Monitoring Research of Zhejiang Province, Hangzhou, Zhejiang310016, China.
- Zhejiang Engineering Research Center for Intelligent Manufacturing of Clinical Diagnostic Equipment, Hangzhou, Zhejiang310016, China.
- Shenzhen Key Laboratory of Functional Proteomics, Department of Chemistry and Research Center for Chemical Biology and Omics Analysis, College of Science, Guangming Advanced Research Institute, Southern University of Sc…
ORCID-Profile: Ruijun Tian, Wei Cui
Förderung
- National Science and Technology Major Project
- Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
Zitieren
APA
Li, K., Duan, Z., Li, K., Wang, Y., Wang, M., Zhang, Y., Tian, R., Fu, C., Yuan, Y., Ang, C., Liu, X., Ma, H., Zhang, J., Zhang, X., & Cui, W. (2026). Subpicogram-Level Quantification of Trace Biomarkers Using an Automated High-Sensitivity Chemiluminescence Immunoassay Technology Based on a Novel Substrate Enhancement Strategy. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6c03190
Vancouver
Li K, Duan Z, Li K, Wang Y, Wang M, Zhang Y, et al. Subpicogram-Level Quantification of Trace Biomarkers Using an Automated High-Sensitivity Chemiluminescence Immunoassay Technology Based on a Novel Substrate Enhancement Strategy. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.6c03190
BibTeX
@article{Li2026,
author = {Li, Kexin and Duan, Zhuonan and Li, Ke and Wang, Yanzhong and Wang, Minjie and Zhang, Yujuan and Tian, Ruijun and Fu, Changying and Yuan, Yushu and Ang, Chaoman and Liu, Xueqing and Ma, Hui and Zhang, Jun and Zhang, Xin and Cui, Wei},
title = {Subpicogram-Level Quantification of Trace Biomarkers Using an Automated High-Sensitivity Chemiluminescence Immunoassay Technology Based on a Novel Substrate Enhancement Strategy},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.6c03190}
}
EUVIMED