EUVIMEDEUVIMED entdecken
Crossref

Self-Cleaning Electrochemical Biosensor Based on MCOF@Ag for Simultaneous Pathogen Detection and Photocatalytic Inactivation

Yun Bai, Libo Xiao, Lixun Cai, Yubin Zhao, Chen Li, Lijiu Xiao, Zhanjun Li, Xu-Jia Hong iD, Jiajia Wang iD

Analytical Chemistry · 18.08.2026 · 98 (32) · 23750-23761

DOI: 10.1021/acs.analchem.6c03095 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 31.07.2026. Verfasst von Yun Bai und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, School of Pharmaceutical Sciences, School of Biomedical Engineering, Guangzhou Medical University, Guangzhou511436, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Staphylococcus aureus, Electrochemical Techniques, Silver. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Basic and Applied Basic Research Foundation of Guangdong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Efficient detection and real-time inactivation of pathogens are critical for the prevention and control of infectious diseases. Herein, based on a Ag nanoparticle-decorated metal-covalent organic framework (MCOF@Ag), a self-cleaning electrochemical biosensor was developed for ultrasensitive bacteria detection and inactivation. The as-synthesized MCOF@Ag (designated as GZHMU-2@Ag) exhibited a unique nanoflowerlike structure, which facilitated efficient electron transfer and significantly enhanced both electrochemical and photocatalytic activities. Staphylococcus aureus was chosen as a pathogen model. By immobilizing S. aureus-specific SA31 aptamers on the GZHMU-2@Ag-based electrode, measurable electrochemical changes were induced by the binding of target bacteria. Therefore, the biosensor enabled the logarithmic quantification of S. aureus across a broad range (1 to 105 CFU/mL), demonstrating a limit of detection of 1 CFU/mL. More importantly, owing to excellent photocatalytic activity, the GZHMU-2@Ag-based electrode achieved 99.4% inactivation of captured bacteria within 20 min of visible light exposure through photocatalytic generation of reactive oxygen species. Subsequent regenerative desorption allowed the electrode to be self-cleaned and reused, demonstrating a satisfactory detection performance. This study provides a strategy for the simultaneous detection and inactivation of pathogens with one MCOF@Ag electrode, highlighting the potential of MCOF-based materials in advanced electrochemical biosensing and antibacterial applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesStaphylococcus aureusElectrochemical TechniquesSilverMetal NanoparticlesCatalysisElectrodesPhotochemical ProcessesAptamers, Nucleotide

Substanzen

SilverAptamers, Nucleotide

Autor:innen und Institutionen

  • School of Public Health, School of Pharmaceutical Sciences, School of Biomedical Engineering, Guangzhou Medical University, Guangzhou511436, China.

ORCID-Profile: Xu-Jia Hong, Jiajia Wang

Förderung

  • National Natural Science Foundation of China
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Bai, Y., Xiao, L., Cai, L., Zhao, Y., Li, C., Xiao, L., Li, Z., Hong, X. J., & Wang, J. (2026). Self-Cleaning Electrochemical Biosensor Based on MCOF@Ag for Simultaneous Pathogen Detection and Photocatalytic Inactivation. Analytical Chemistry, 98(32), 23750-23761. https://doi.org/10.1021/acs.analchem.6c03095

Vancouver

Bai Y, Xiao L, Cai L, Zhao Y, Li C, Xiao L, et al. Self-Cleaning Electrochemical Biosensor Based on MCOF@Ag for Simultaneous Pathogen Detection and Photocatalytic Inactivation. Analytical Chemistry. 2026;98(32):23750-23761. doi:10.1021/acs.analchem.6c03095

BibTeX
@article{Bai2026,
  author = {Bai, Yun and Xiao, Libo and Cai, Lixun and Zhao, Yubin and Li, Chen and Xiao, Lijiu and Li, Zhanjun and Hong, Xu-Jia and Wang, Jiajia},
  title = {Self-Cleaning Electrochemical Biosensor Based on MCOF@Ag for Simultaneous Pathogen Detection and Photocatalytic Inactivation},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {32},
  pages = {23750--23761},
  doi = {10.1021/acs.analchem.6c03095}
}