EUVIMEDEUVIMED entdecken
Crossref

Ag+ dual-driven self-calibration for high-performance dual-photoelectrode self-powered ratiometric sensing

Yanru Zhang, Xuechen Zhang, Xue Fan, Hongye Liu, Jingyao Peng, Wenbo Song, Daqian Song

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2025.344908 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Yanru Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Jilin University, Changchun, 130012, China. Hauptthemen laut MEDLINE: Silver, Ochratoxins, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite significant advances in the dual-photoelectrode self-powered sensor, the single-signal output mode usually brings false positives/negatives from environmental interference and instrumental fluctuations, which fails to meet the requirement of accurate and sensitive detection of low-level markers in food safety and environmental monitoring. To address this critical issue, we herein report an Ag+ dual-driven self-calibrating strategy for self-powered ratiometric assay. In the ZnIn2S4//Bi2S3/CuTCPP dual-photoelectrode system, the synergy effect of Ag+-triggered DNAzyme cleavage and cation exchange on ZnIn2S4 photoanode produces a stable and weak reference signal. Specifically, Ag+-triggered DNAzyme cleavages the 3D DNA walker-amplified signal label, and the ion exchange between Ag+ and ZnIn2S4 quenches the reference signal simultaneously via electron migration pathway change. A proof-of-concept detection of mycotoxin ochratoxin A in the crop samples is demonstrated. The ratiometric self-powered sensor demonstrates a wide linear range of 10-6 -102 ng/mL with an ultralow detection limit of 0.20 fg/mL. This work breaks the limits of single-signal self-powered detection, providing a brand-new idea for developing portable devices with great potential of on-site testing in the field environment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SilverOchratoxinsElectrochemical TechniquesBiosensing TechniquesElectrodesDNA, CatalyticLimit of DetectionIndiumPhotochemical ProcessesCalibration

Stichwörter der Autor:innen

Ag(+) dual-drivenDual-photoelectrodeSelf-calibratingSelf-powered sensorZ-Scheme heterojunction

Substanzen

SilverOchratoxinsochratoxin ADNA, CatalyticIndium

Autor:innen und Institutionen

  • College of Chemistry, Jilin University, Changchun, 130012, China.
  • College of Chemistry, Jilin University, Changchun, 130012, China. Electronic address: wbsong@jlu.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, Y., Zhang, X., Fan, X., Liu, H., Peng, J., Song, W., & Song, D. (2026). Ag+ dual-driven self-calibration for high-performance dual-photoelectrode self-powered ratiometric sensing. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344908

Vancouver

Zhang Y, Zhang X, Fan X, Liu H, Peng J, Song W, et al. Ag+ dual-driven self-calibration for high-performance dual-photoelectrode self-powered ratiometric sensing. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2025.344908

BibTeX
@article{Zhang2026,
  author = {Zhang, Yanru and Zhang, Xuechen and Fan, Xue and Liu, Hongye and Peng, Jingyao and Song, Wenbo and Song, Daqian},
  title = {Ag+ dual-driven self-calibration for high-performance dual-photoelectrode self-powered ratiometric sensing},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2025.344908}
}
Kostenlos starten →