EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting

Katharina E Dietmann iD, Guanting Guo iD, Jacqueline Aschauer, Tarek Eissa iD, Frank Fleischmann, Mihaela Žigman iD

Analytical Chemistry · 30.06.2026 · 98 (25) · 18722-18734

DOI: 10.1021/acs.analchem.6c01358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 17.06.2026. Verfasst von Katharina E Dietmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Experimental Physics-Laser Physics, Ludwig-Maximilians-Universität München, 85748 Garching, Germany. Hauptthemen laut MEDLINE: Workflow, Blood Specimen Collection. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ludwig-Maximilians-Universit?t M?nchen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Standardized preanalytical sample handling is a cornerstone of reliable molecular analytics, particularly where subtle multimolecular differences can drive biological interpretation. In different clinical studies, blood-based samples are often processed using varying workflows, and the influence of individual technical parameters remains poorly quantified. In particular, preanalytical differences can limit study comparability and complicate the robust evaluation of the approach for different applications and specific medical questions. Here, we systematically investigate the effects of major preanalytical variables on infrared molecular fingerprinting (IMF) of blood serum and plasma, performed via Fourier transform infrared (FTIR) spectroscopy. We examine the impacts of venous blood draw tube types, tube fill volumes, delay times prior to centrifugation, centrifugation conditions, freezing and thawing procedures, and delay times between final sample preparation and infrared spectroscopy. We found that the type of blood collection tube, the fill volume of the tube, a delay of more than 4 h before centrifugation, more than two freeze-thaw cycles, and delays prior to measurement can result in systematic changes in infrared fingerprints that are detectable through multivariate analysis and machine learning. Importantly, for most conditions, the magnitude of parameter-related spectral variation remains smaller than the intrinsic biological variability across individuals, supporting the feasibility of IMF for realistic clinical settings. The presented results provide actionable guidance and a basis for harmonizing preanalytical workflows, reducing preanalytical confounding in IMF-based biofluid analysis, and improving cross-study comparability, with relevance that may generalize to other molecular profiling technologies, clinical studies, and biobanking.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WorkflowBlood Specimen CollectionHumansSpectroscopy, Fourier Transform InfraredReproducibility of Results

Autor:innen und Institutionen

  • Department of Experimental Physics-Laser Physics, Ludwig-Maximilians-Universität München, 85748 Garching, Germany.
  • Laboratory for Attosecond Physics, Max Planck Institute of Quantum Optics, 85748 Garching, Germany.
  • School of Life Sciences, Technical University of Munich (TUM), 85354 Freising, Germany.
  • University Hospital, Ludwig-Maximilians-Universität München, 81377 München, Germany.
  • Faculty of Medicine, Institute of Pathology, Ludwig-Maximilians-Universität München, 80337 München, Germany.

ORCID-Profile: Katharina E Dietmann, Guanting Guo, Tarek Eissa, Mihaela Žigman

Förderung

  • Ludwig-Maximilians-Universit?t M?nchen

Zitieren

APA

Dietmann, K. E., Guo, G., Aschauer, J., Eissa, T., Fleischmann, F., & Žigman, M. (2026). Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting. Analytical Chemistry, 98(25), 18722-18734. https://doi.org/10.1021/acs.analchem.6c01358

Vancouver

Dietmann KE, Guo G, Aschauer J, Eissa T, Fleischmann F, Žigman M. Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting. Analytical Chemistry. 2026;98(25):18722-18734. doi:10.1021/acs.analchem.6c01358

BibTeX
@article{Dietmann2026,
  author = {Dietmann, Katharina E and Guo, Guanting and Aschauer, Jacqueline and Eissa, Tarek and Fleischmann, Frank and Žigman, Mihaela},
  title = {Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {25},
  pages = {18722--18734},
  doi = {10.1021/acs.analchem.6c01358}
}
Kostenlos starten →