EUVIMEDEUVIMED entdecken
Crossref

Aerosol Jet Printed Ag Micropillar Arrays Coupled with PEDOT:PSS for High-Performance Electrochemical Sensing of Niclosamide

Yunhang Liu, Hao Yi iD, Huajun Cao, Jun Luo

Analytical Chemistry · 19.05.2026 · 98 (19) · 14460-14472

DOI: 10.1021/acs.analchem.6c01119 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 06.05.2026. Verfasst von Yunhang Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Mechanical Transmission for Advanced Equipment, Chongqing University, Chongqing 400044, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Chongqing Science and Technology Commission, Opening Project of State Key Laboratory of Intelligent Manufacturing Equipment and Technology, Natural Science Foundation of Chongqing.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, an aerosol-jet-printed silver micropillar array was introduced onto the surface of a screen-printed carbon electrode (SPCE) and further coated with a poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) functional film, yielding a three-dimensional hierarchical electrode for high-performance electrochemical detection of niclosamide (NA). The silver micropillar arrays form a three-dimensional microelectrode network on the working electrode surface, where the pillar tops and sidewalls markedly increase the electrochemically active area and facilitate mass transport toward the electrode interface, thereby enhancing analyte flux and amplifying the Faradaic response. In addition, PEDOT:PSS as a mixed ionic-electronic conductor, establishes a continuous and stable reaction interface on the silver-pillar scaffold, which not only improves interfacial wettability and charge/ion transport but also promotes interfacial enrichment of NA via its functionalized polymer network. Benefiting from the synergistic effects of three-dimensional structural amplification and conductive-polymer-mediated interfacial regulation, the fabricated Ag@PEDOT:PSS/SPCE sensor exhibits a good linear response over 0.01-15 μM with a limit of detection as low as 1.73 nM. Meanwhile, the sensor demonstrates excellent repeatability, reproducibility, and anti-interference performance, and it was successfully applied to the quantitative determination of NA in tap water and oolong tea samples with satisfactory recoveries and accuracy, indicating strong potential for practical applications.

Autor:innen und Institutionen

  • State Key Laboratory of Mechanical Transmission for Advanced Equipment, Chongqing University, Chongqing 400044, China.
  • State Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.

ORCID-Profile: Hao Yi

Förderung

  • Chongqing Science and Technology Commission
  • Opening Project of State Key Laboratory of Intelligent Manufacturing Equipment and Technology
  • Natural Science Foundation of Chongqing
  • National Natural Science Foundation of China (NSFC)

Zitieren

APA

Liu, Y., Yi, H., Cao, H., & Luo, J. (2026). Aerosol Jet Printed Ag Micropillar Arrays Coupled with PEDOT:PSS for High-Performance Electrochemical Sensing of Niclosamide. Analytical Chemistry, 98(19), 14460-14472. https://doi.org/10.1021/acs.analchem.6c01119

Vancouver

Liu Y, Yi H, Cao H, Luo J. Aerosol Jet Printed Ag Micropillar Arrays Coupled with PEDOT:PSS for High-Performance Electrochemical Sensing of Niclosamide. Analytical Chemistry. 2026;98(19):14460-14472. doi:10.1021/acs.analchem.6c01119

BibTeX
@article{Liu2026,
  author = {Liu, Yunhang and Yi, Hao and Cao, Huajun and Luo, Jun},
  title = {Aerosol Jet Printed Ag Micropillar Arrays Coupled with PEDOT:PSS for High-Performance Electrochemical Sensing of Niclosamide},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {19},
  pages = {14460--14472},
  doi = {10.1021/acs.analchem.6c01119}
}
Kostenlos starten →