In Vivo Ratiometric Electrochemical Detection of Hypochlorous Acid in Living Brains Using a Methylene Blue-Benzoyl-Based Microsensor
Analytical Chemistry · 20.01.2026 · 98 (2) · 1710-1717
DOI: 10.1021/acs.analchem.5c06562 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 05.01.2026. Verfasst von Xingchen Tan und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China. Hauptthemen laut MEDLINE: Hypochlorous Acid, Methylene Blue, Electrochemical Techniques, Brain. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Natural Science Foundation of Hunan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Hypochlorous acid (HClO), a reactive chlorine species produced by myeloperoxidase (MPO), contributes to neuroinflammation and oxidative stress implicated in neurodegenerative disorders. However, real-time quantification of HClO in the living brain remains challenging due to the lack of selective, miniaturized tools. Here, we report a ratiometric electrochemical microsensor based on a newly synthesized methylene blue-benzoyl (MB-Bz) probe for in vivo detection of HClO in the brain. The MB-Bz probe was immobilized on a three-dimensional (3D) electrochemically reduced graphene oxide-single-walled carbon nanotube (ERGO-SWCNT) nanocomposite-modified carbon fiber microelectrode. Upon reaction with HClO, the probe undergoes oxidative cleavage at the imine linkage adjacent to the benzoyl group, releasing benzoate and regenerating methylene blue, thereby producing two well-separated redox peaks for ratiometric quantification. The optimized microsensor exhibits a linear response toward HClO in the range of 2-40 μM (limit of detection 0.07 μM, S/N = 3) with excellent selectivity, stability, and reproducibility. When implanted into rat and mouse brains, the microsensor enables in vivo, region-specific electrochemical monitoring of HClO. Notably, elevated HClO levels are observed in the cortex, striatum, and hippocampus of PD model mice relative to normal mice, consistent with MPO-mediated oxidative stress. This work provides a molecularly engineered electrochemical platform for in vivo HClO analysis in living brain tissue, offering a valuable approach to investigate reactive chlorine species in neurodegeneration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, Hunan 411201, P. R. China.
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, P. R. China.
ORCID-Profile: Haoyue Xiang, Hui Gu
Förderung
- Natural Science Foundation of Hunan Province
- National Natural Science Foundation of China
Zitieren
APA
Tan, X., Wang, W., Luo, C., Wang, Q., Wang, H., Pan, H., Xiang, H., & Gu, H. (2026). In Vivo Ratiometric Electrochemical Detection of Hypochlorous Acid in Living Brains Using a Methylene Blue-Benzoyl-Based Microsensor. Analytical Chemistry, 98(2), 1710-1717. https://doi.org/10.1021/acs.analchem.5c06562
Vancouver
Tan X, Wang W, Luo C, Wang Q, Wang H, Pan H, et al. In Vivo Ratiometric Electrochemical Detection of Hypochlorous Acid in Living Brains Using a Methylene Blue-Benzoyl-Based Microsensor. Analytical Chemistry. 2026;98(2):1710-1717. doi:10.1021/acs.analchem.5c06562
BibTeX
@article{Tan2026,
author = {Tan, Xingchen and Wang, Wenhui and Luo, Cong and Wang, Qian and Wang, Huihui and Pan, Hui and Xiang, Haoyue and Gu, Hui},
title = {In Vivo Ratiometric Electrochemical Detection of Hypochlorous Acid in Living Brains Using a Methylene Blue-Benzoyl-Based Microsensor},
journal = {Analytical Chemistry},
year = {2026},
volume = {98},
number = {2},
pages = {1710--1717},
doi = {10.1021/acs.analchem.5c06562}
}
EUVIMED