Integrated Analytical System for Comprehensive Two-Dimensional Enantio-Gas Chromatography and Low-Pressure Gas Chromatography Mass Spectrometry Utilizing a Switching Valve: Design and Optimization
Analytical Chemistry · 25.11.2025 · 97 (46) · 25406-25415
DOI: 10.1021/acs.analchem.5c05852 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 12.11.2025. Verfasst von Giorgia Rinaldi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Messina Institute of Technology c/o Department of ChemicalBiological, Pharmaceutical and Environmental Sciences, former Veterinary School, University…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Shimadzu, Merck Life Science.
Abstract (Originalsprache)
An analytical system was developed to perform both comprehensive two-dimensional enantio-gas chromatography mass spectrometry with the second-dimension column working under low-pressure conditions (eGC×LP-GC-QMS) and low-pressure gas chromatography mass spectrometry (LP-GC-QMS) analysis, without any changes to the instrumental setup. This is achieved using a switching valve, which also allows for back-flushing of the first-dimension column, thereby generating a flexible and powerful analytical platform. The eGC×LP-GC-QMS configuration can provide both targeted and untargeted information in a single run. In this research, it is employed for the analysis of 56 pesticides (without considering isomers), with the added capability of the backflush mode, effectively removing high-boiling compounds extracted from the matrix and improving sample throughput and system robustness, without major concerns regarding sample preparation. The first-dimension is a chiral column, which enables the separation of seven enantiomers: acephate, benoxacor, chlorflurecol, dibrom, fipronil, methamidophos, and propetamphos. The second-dimension is a wide-bore column (5 m × 0.53 mm I.D. × 0.53 μm df) operating under vacuum conditions. Thanks to the use of a switching valve, it is possible to directly perform LP-GC-QMS analysis, enabling the investigation of a broader range of compounds in terms of boiling point. The operability range of volatile analytes was evaluated for both configurations by injecting different alkane mixtures: C7-C30 for the eGC×LP-GC-QMS configuration and C7-C40 for the LP-GC-QMS configuration.
Autor:innen und Institutionen
- Messina Institute of Technology c/o Department of ChemicalBiological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc, 98168 Messina, Italy.
- Department of Mathematical and Computer Science, Physical Sciences and Earth Sciences, University of Messina, Viale F. Stagno d'Alcontres 31, 98166 Messina, Italy.
- Chromaleont s.r.l., c/o Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Viale G. Palatucci snc, 98168 Messina, Italy.
ORCID-Profile: Mariosimone Zoccali
Förderung
- Shimadzu
- Merck Life Science
Zitieren
APA
Rinaldi, G., Ferracane, A., Zoccali, M., & Mondello, L. (2025). Integrated Analytical System for Comprehensive Two-Dimensional Enantio-Gas Chromatography and Low-Pressure Gas Chromatography Mass Spectrometry Utilizing a Switching Valve: Design and Optimization. Analytical Chemistry, 97(46), 25406-25415. https://doi.org/10.1021/acs.analchem.5c05852
Vancouver
Rinaldi G, Ferracane A, Zoccali M, Mondello L. Integrated Analytical System for Comprehensive Two-Dimensional Enantio-Gas Chromatography and Low-Pressure Gas Chromatography Mass Spectrometry Utilizing a Switching Valve: Design and Optimization. Analytical Chemistry. 2025;97(46):25406-25415. doi:10.1021/acs.analchem.5c05852
BibTeX
@article{Rinaldi2025,
author = {Rinaldi, Giorgia and Ferracane, Antonio and Zoccali, Mariosimone and Mondello, Luigi},
title = {Integrated Analytical System for Comprehensive Two-Dimensional Enantio-Gas Chromatography and Low-Pressure Gas Chromatography Mass Spectrometry Utilizing a Switching Valve: Design and Optimization},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {46},
pages = {25406--25415},
doi = {10.1021/acs.analchem.5c05852}
}