EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

Vladislav V Lobodin iD, Yensil Park, Charles E A Finney

Analytical Chemistry · 07.07.2026 · 98 (26) · 19493-19499

DOI: 10.1021/acs.analchem.6c00257 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 22.05.2026. Verfasst von Vladislav V Lobodin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6472, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC-MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion-molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Autor:innen und Institutionen

  • Buildings and Transportation Science Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6472, United States.

ORCID-Profile: Vladislav V Lobodin

Förderung

  • Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy

Zitieren

APA

Lobodin, V. V., Park, Y., & Finney, C. E. A. (2026). Hydrogen Analysis by Gas Chromatography–Mass Spectrometry. Analytical Chemistry, 98(26), 19493-19499. https://doi.org/10.1021/acs.analchem.6c00257

Vancouver

Lobodin VV, Park Y, Finney CEA. Hydrogen Analysis by Gas Chromatography–Mass Spectrometry. Analytical Chemistry. 2026;98(26):19493-19499. doi:10.1021/acs.analchem.6c00257

BibTeX
@article{Lobodin2026,
  author = {Lobodin, Vladislav V and Park, Yensil and Finney, Charles E A},
  title = {Hydrogen Analysis by Gas Chromatography–Mass Spectrometry},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {26},
  pages = {19493--19499},
  doi = {10.1021/acs.analchem.6c00257}
}
Kostenlos starten →