Fluorescent Microneedle Sensor Array for Continuously Monitoring Sodium and Hydrogen Ion Concentrations in Interstitial Fluid and Its Application in Diabetes Complication Management
Analytical Chemistry · 2026
DOI: 10.1021/acs.analchem.5c05566 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Rui Jiang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Human Phenome Institute, Fudan University, Shanghai 200433, P. R. China. Hauptthemen laut MEDLINE: Sodium, Hydrogen, Extracellular Fluid, Needles. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.
Themen: Diabetes mellitus
Abstract (Originalsprache)
The homeostasis and regulation of sodium and hydrogen ions are crucial in the pathophysiology of diabetes, as metabolic dysregulation often leads to electrolyte disturbances and acid-base imbalance. Current diagnostic tools, such as blood gas analysis in a hospital, are invasive, time-consuming, and strictly demanding professional skills. To cope with this problem, we have worked out a minimally invasive, dual-ion-sensitive microneedle sensor array to simultaneously monitor interstitial sodium and hydrogen ion concentrations. By integrating two ion-sensitive fluorescent materials and a long-lifetime phosphorescent reference material into hydrogel-based microneedles, we fabricated a fluorescence microneedle sensor (FMNS) array that possesses sufficient mechanical strength and flexibility to penetrate the stratum corneum and to contact the interstitial fluid. The array demonstrates fully reversible responses to variations of hydrogen and sodium ions and is capable of measuring the concentration of both ions with high sensitivity, good selectivity, high accuracy, and quick response. In vivo experiments on diabetic and diabetic ketoacidosis mouse models showed that the measured values correlate well with that from the blood gas analysis, confirming the high accuracy of the FMNS array. Moreover, the full reversibility and the quick response of the FMNS array suggest a minimally invasive alternative to blood gas analysis, enabling real-time and home-based measurement of multiple critical parameters for the comprehensive management of diabetes complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Human Phenome Institute, Fudan University, Shanghai 200433, P. R. China.
ORCID-Profile: Xu-Dong Wang
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Jiang, R., Xu, Y., Yang, E., Liang, J., Yang, Y., Yu, L., Wang, P., & Wang, X. D. (2026). Fluorescent Microneedle Sensor Array for Continuously Monitoring Sodium and Hydrogen Ion Concentrations in Interstitial Fluid and Its Application in Diabetes Complication Management. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c05566
Vancouver
Jiang R, Xu Y, Yang E, Liang J, Yang Y, Yu L, et al. Fluorescent Microneedle Sensor Array for Continuously Monitoring Sodium and Hydrogen Ion Concentrations in Interstitial Fluid and Its Application in Diabetes Complication Management. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c05566
BibTeX
@article{Jiang2026,
author = {Jiang, Rui and Xu, Ying and Yang, Enlai and Liang, Jiahao and Yang, Yang and Yu, Luqiang and Wang, Pengfei and Wang, Xu-Dong},
title = {Fluorescent Microneedle Sensor Array for Continuously Monitoring Sodium and Hydrogen Ion Concentrations in Interstitial Fluid and Its Application in Diabetes Complication Management},
journal = {Analytical Chemistry},
year = {2026},
doi = {10.1021/acs.analchem.5c05566}
}
EUVIMED