EUVIMEDEUVIMED entdecken
Crossref

Dual-Mode Electrochemical and Electrochemiluminescent Aptamer Biosensors for Point-of-Care Detection of Cardiac Troponin I

Mingang Liao, Zhuoliang Hu, Xilin Chen, Mengjie Chen, Zelin Yang, Jianbin Pan, Duanping Sun iD

Analytical Chemistry · 12.08.2025 · 97 (31) · 16885-16895

DOI: 10.1021/acs.analchem.5c02086 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 15.07.2025. Verfasst von Mingang Liao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Drug Research and Development, the Second Clinical Medical School (Guangdong Second Provincial General Hospital), Guangdong Pharmaceutical…. Hauptthemen laut MEDLINE: Troponin I, Aptamers, Nucleotide, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Basic and Applied Basic Research Foundation of Guangdong Province, Department of Education of Guangdong Province, Guangdong Pharmaceutical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acute myocardial infarction (AMI), a leading cause of global mortality, requires the rapid and accurate detection of cardiac troponin I (cTnI) for prompt intervention. To address this, we present an innovative dual-mode electrochemiluminescence-electrochemical (ECL-EC) aptasensor for point-of-care detection of cTnI. The platform employs Fe3O4/PEI/CdS quantum dots (QDs) (FePQ) functionalized with a Tro6 aptamer as ECL-active capture probes and ferrocene (Fc)-encapsulated UiO-66-NH2 (UFc) conjugated with a Tro4 aptamer as dual-functional signal probes. Upon cTnI binding, a sandwich complex forms, enabling dual-signal transduction: ECL signal attenuation is achieved through energy transfer or electron transfer between FePQ and proximal UFc and enhanced square wave voltammetry (SWV) response from accumulated UFc moieties. This ECL-EC mechanism enables self-verification, significantly reducing false signals, while achieving a wide linear range from 0.001 to 100 ng/mL with low detection limits (0.49 and 0.74 pg/mL) for 60 min. Notably, the dual-mode detection system also demonstrates remarkable consistency for cTnI quantification in clinical samples. The integration of magnetic separation, aptamer-based recognition, and UiO-66-NH2-enhanced signal amplification ensures clinical practicality. The system demonstrates exceptional specificity, reproducibility, and stability in human serum analysis, not only providing a transformative solution for point-of-care AMI diagnostics but also establishing a versatile framework for developing multimodal biosensors targeting other biomarkers, advancing precision medicine in cardiovascular care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin IAptamers, NucleotideBiosensing TechniquesElectrochemical TechniquesLuminescent MeasurementsPoint-of-Care SystemsHumansLimit of DetectionQuantum DotsFerrous Compounds

Substanzen

Troponin IAptamers, NucleotideFerrous Compounds

Autor:innen und Institutionen

  • Center for Drug Research and Development, the Second Clinical Medical School (Guangdong Second Provincial General Hospital), Guangdong Pharmaceutical University, Guangzhou, Guangdong 510006, China.
  • State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, Jiangsu 210093, China.

ORCID-Profile: Duanping Sun

Förderung

  • Basic and Applied Basic Research Foundation of Guangdong Province
  • Department of Education of Guangdong Province
  • Guangdong Pharmaceutical University
  • National Natural Science Foundation of China
  • Guangzhou Basic and Applied Basic Research Foundation

Zitieren

APA

Liao, M., Hu, Z., Chen, X., Chen, M., Yang, Z., Pan, J., & Sun, D. (2025). Dual-Mode Electrochemical and Electrochemiluminescent Aptamer Biosensors for Point-of-Care Detection of Cardiac Troponin I. Analytical Chemistry, 97(31), 16885-16895. https://doi.org/10.1021/acs.analchem.5c02086

Vancouver

Liao M, Hu Z, Chen X, Chen M, Yang Z, Pan J, et al. Dual-Mode Electrochemical and Electrochemiluminescent Aptamer Biosensors for Point-of-Care Detection of Cardiac Troponin I. Analytical Chemistry. 2025;97(31):16885-16895. doi:10.1021/acs.analchem.5c02086

BibTeX
@article{Liao2025,
  author = {Liao, Mingang and Hu, Zhuoliang and Chen, Xilin and Chen, Mengjie and Yang, Zelin and Pan, Jianbin and Sun, Duanping},
  title = {Dual-Mode Electrochemical and Electrochemiluminescent Aptamer Biosensors for Point-of-Care Detection of Cardiac Troponin I},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {31},
  pages = {16885--16895},
  doi = {10.1021/acs.analchem.5c02086}
}
Kostenlos starten →