EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Biological Recognition-Based Electrochemical Aptasensor for Point-of-Care Detection of cTnI

Jianfeng Ma iD, Lin Feng, Jie Li, Dan Zhu, Lianhui Wang, Shao Su iD

Biosensors · 2023

DOI: 10.3390/bios13070746 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2023. Verfasst von Jianfeng Ma und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), …. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques, Myocardial Infarction. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Leading-edge Technology Program of Jiangsu Natural Science Foundation, "Belt and Road" Innovation Cooperation Project of Jiangsu, "Six Talents Peak" Foundation of Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As a “gold standard biomarker”, cardiac troponin I (cTnI) is widely used to diagnose acute myocardial infarction (AMI). For an early clinical diagnosis of AMI, it is necessary to develop a facile, fast and on-site device for cTnI detection. According to this demand, a point-of-care electrochemical aptasensor was developed for cTnI detection by coupling the advantages of screen-printed carbon electrode (SPCE) with those of an aptamer. Thiol and methylene blue (MB) co-labelled aptamer (MB-Apt-SH) was assembled on the surface of hierarchical flower-like gold nanostructure (HFGNs)-decorated SPCE (SPCE-HFGNs) to recognize and analyze cTnI. In the presence of cTnI, the specific biological recognition reaction between cTnI and aptamer caused the decrease in electrochemical signal. Under the optimal condition, this designed aptasensor showed wide linear range (10 pg/mL–100 ng/mL) and low detection limit for (8.46 pg/mL) for cTnI detection with high selectivity and stability. More importantly, we used a mobile phone coupled with a simple APP to efficiently detect cTnI in 10 μL 100% human serum samples, proving that this aptasensor has a promising potential in point-of-care testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesMyocardial InfarctionHumansLimit of DetectionTroponin IPoint-of-Care SystemsElectrochemical TechniquesCarbon

Stichwörter der Autor:innen

aptasensorcardiac troponin Ielectrochemical detectionpoint-of-care testing

Substanzen

Troponin IAptamers, NucleotideCarbon

Autor:innen und Institutionen

  • State Key Laboratory of Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Na…

ORCID-Profile: Jianfeng Ma, Shao Su

Förderung

  • Leading-edge Technology Program of Jiangsu Natural Science Foundation
  • "Belt and Road" Innovation Cooperation Project of Jiangsu
  • "Six Talents Peak" Foundation of Jiangsu Province
  • Natural Science Foundation of the Jiangsu Higher Education Institutions
  • “Belt and Road” Innovation Cooperation Project of Jiangsu
  • “Six Talents Peak” Foundation of Jiangsu Province

Zitieren

APA

Ma, J., Feng, L., Li, J., Zhu, D., Wang, L., & Su, S. (2023). Biological Recognition-Based Electrochemical Aptasensor for Point-of-Care Detection of cTnI. Biosensors. https://doi.org/10.3390/bios13070746

Vancouver

Ma J, Feng L, Li J, Zhu D, Wang L, Su S. Biological Recognition-Based Electrochemical Aptasensor for Point-of-Care Detection of cTnI. Biosensors. 2023. doi:10.3390/bios13070746

BibTeX
@article{Ma2023,
  author = {Ma, Jianfeng and Feng, Lin and Li, Jie and Zhu, Dan and Wang, Lianhui and Su, Shao},
  title = {Biological Recognition-Based Electrochemical Aptasensor for Point-of-Care Detection of cTnI},
  journal = {Biosensors},
  year = {2023},
  doi = {10.3390/bios13070746}
}
Kostenlos starten →