Electrochemical Biosensor Utilizing Low-Susceptibility Macrocyclic Stapled Peptide to Mitigate Biofouling for Reliable Protein Detection in Human Serum
Analytical Chemistry · 08.04.2025 · 97 (13) · 7343-7351
DOI: 10.1021/acs.analchem.4c07024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 26.03.2025. Verfasst von Yanxin Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao Univ…. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Biofouling, Peptides. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Technology Research and Development Program of Shandong Province.
Abstract (Originalsprache)
Antifouling peptide surfaces have garnered increasing attention due to their immense potential across various biochemical fields. Cyclic peptides, in particular, demonstrate greater resistance to nonspecific substance adsorption compared to regular linear peptides. Herein, inspired by the macrocyclization method, we introduced two non-natural amino acids (R8 and S5) to cyclize the typical low-fouling sequence (EKEKEK) head-to-tail, thereby protecting terminal amino acids and reducing proteolytic susceptibility. This approach resulted in the formation of a novel stapled peptide (SP), which resisted protease hydrolysis and enhanced the antifouling capabilities of the SP-based biosensor compared to the conventional linear peptide (LP), demonstrated by electrochemical testing and fluorescence imaging experiments. Theoretically, molecular dynamics simulations were employed to calculate binding energies between the peptides and carboxypeptidase Y (CPY), and the results showcased a stronger binding affinity of LP with CPY, further confirming the lower proteolytic susceptibility of the engineered SP. Remarkably, the SP-based biosensor demonstrated high sensitivity in detecting the model target of carcinoembryonic antigen, with a limit of detection of 0.49 pg/mL. Moreover, clinical serum samples analyzed using the SP-based biosensor showed excellent concordance with hospital diagnostic methods, underscoring its exceptional accuracy and further highlighting the superiorities of the engineered SP structures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China.
ORCID-Profile: Gao-Chao Fan, Xiliang Luo
Förderung
- National Natural Science Foundation of China
- Key Technology Research and Development Program of Shandong Province
Zitieren
APA
Li, Y., Liu, Y., Zhan, Y., Wang, Y., Wang, C., Fan, G. C., & Luo, X. (2025). Electrochemical Biosensor Utilizing Low-Susceptibility Macrocyclic Stapled Peptide to Mitigate Biofouling for Reliable Protein Detection in Human Serum. Analytical Chemistry, 97(13), 7343-7351. https://doi.org/10.1021/acs.analchem.4c07024
Vancouver
Li Y, Liu Y, Zhan Y, Wang Y, Wang C, Fan GC, et al. Electrochemical Biosensor Utilizing Low-Susceptibility Macrocyclic Stapled Peptide to Mitigate Biofouling for Reliable Protein Detection in Human Serum. Analytical Chemistry. 2025;97(13):7343-7351. doi:10.1021/acs.analchem.4c07024
BibTeX
@article{Li2025,
author = {Li, Yanxin and Liu, Yilu and Zhan, Yinan and Wang, Yudong and Wang, Congkai and Fan, Gao-Chao and Luo, Xiliang},