EUVIMEDEUVIMED entdecken
Crossref

Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers

Zhiying Shao, Kezuo Di, Jie Wei iD, Cunhao Fan, Xujing Feng, Huadong Heng, Kun Wang iD

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.4c05553 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zhiying Shao und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, PR China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Hydrogels, Glucose, Biosensing Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key R&D Program of Zhenjiang City.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional wearable flexible sensing systems typically comprise three components: a flexible substrate that contacts the skin, a signal processing module, and a signal output module. These components function relatively independently, resulting in a complex system that lacks sufficient integration. Therefore, developing an integrated wearable flexible sensing system by combining the flexible substrate, the signal processing module, and the signal output module not only enhances performance and comfort, but also reduces manufacturing costs and the risk of failure. Hydrogel substrates are particularly advantageous due to their excellent biocompatibility, flexibility, and encapsulation capabilities. Herein, we designed an integrated wearable flexible sensing system using an agarose hydrogel to encapsulate biological oxidative enzymes (e.g., glucose oxidase (GOx), lactate oxidase, and ethanol oxidase) and silver nanowires-polydopamine (Ag NWs-PB) as the signal processing module and a color-changing TMB probe as the signal output module. Additionally, we incorporated a polydimethylsiloxane-silicon dioxide patch to collect sweat for detecting physiological markers (e.g., glucose, lactate, and ethanol). An example of the application to facilitate visual detection of glucose in sweat was developed by encapsulating GOx as a biological oxidative enzyme in a sensing system. The system provides results within 3.5 min and operates within a linear range of 0.02 to 5.00 mmol/L, achieving a limit of detection of 0.011 mmol/L. This innovation not only presents a more integrated and portable solution for wearable hydrogel systems, but also introduces a new, feasible method for detecting human physiological markers through a straightforward detection process.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesHydrogelsGlucoseBiosensing TechniquesHumansGlucose OxidaseBiomarkersNanowiresSilverSweatLactic AcidEthanolPolymersIndolesEnzymes, ImmobilizedAlcohol OxidoreductasesMixed Function Oxygenases

Substanzen

HydrogelsGlucose OxidaseBiomarkersGlucoseSilverpolydopamineLactic AcidEthanolPolymersIndoles

Autor:innen und Institutionen

  • School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, PR China.
  • School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang 212013, PR China.

ORCID-Profile: Jie Wei, Kun Wang

Förderung

  • National Natural Science Foundation of China
  • Key R&D Program of Zhenjiang City

Zitieren

APA

Shao, Z., Di, K., Wei, J., Fan, C., Feng, X., Heng, H., & Wang, K. (2025). Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c05553

Vancouver

Shao Z, Di K, Wei J, Fan C, Feng X, Heng H, et al. Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c05553

BibTeX
@article{Shao2025,
  author = {Shao, Zhiying and Di, Kezuo and Wei, Jie and Fan, Cunhao and Feng, Xujing and Heng, Huadong and Wang, Kun},
  title = {Integrated Wearable Flexible Hydrogel Patch Sensing System for the Detection of Physiological Markers},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.4c05553}
}
Kostenlos starten →